What should I do if the refrigerator trips and leaks
Leakage of the moisture-proof wire of the freezer The leakage of the moisture-proof wire of the freezer is mainly manifested by the frequent on and off of the overload protection relay that is turned on after the power is turned on, resulting in the compressor of the freezer cannot be turned on, and the cabinet of the freezer is charged. Hemp inductance will appear when touched by hand, and it is generally common in refrigerators with a long service life. At this time, we can use some insulating sleeves to cover the moisture-proof wires. It is best to remove the old wires and replace them with new rubber insulated wires.
1. Moisture-proof wire leakage of the freezer
The leakage of the moisture-proof wire of the freezer is mainly manifested as the frequent on and off of the overload protection relay that is turned on after the power is turned on, which causes the compressor of the freezer to not be turned on, and also causes the cabinet of the freezer to be charged. Hemp inductance appears, and it is generally common in refrigerators with a long service life. At this time, we can use some insulating sleeves to cover the moisture-proof wires. It is best to remove the old wires and replace them with new rubber insulated wires.
When encountering such problems, it is best to power off the freezer to prevent accidents. Especially in supermarkets, convenience stores and other places, the passenger flow is relatively large. In the event of an accident, the loss will not only be money, but also personal accidents.
2. Leakage of the thermostat of the freezer
The leakage phenomenon of the thermostat of the freezer is mainly manifested as:
There will be numbness inductance when our hands touch the cabinet of the freezer, but the compressor is operating normally and the temperature in the cabinet is normal. Since most thermostats are installed on the inner wall of the freezer, the temperature changes in the freezer will cause condensation around the thermostat. When the condensed water flows into the thermostat, the resistance value between the electrical contact of the thermostat of the freezer and the cabinet will decrease, which causes the cabinet to become charged. For this phenomenon, we can eliminate this problem by regularly defrosting, frequently erasing water in the freezer, and preventing condensed water from flowing into the thermostat. However, at the same time, we should also pay attention to frequently cleaning the temperature controller bakelite frame of the freezer and some surrounding dirt, mainly because the dirt will also cause leakage after absorbing moisture.
Therefore, we still need to maintain the freezer from time to time so as to prevent this leakage phenomenon and effectively extend the service life of the freezer.

Related Info
What are the noteworthy issues in central air conditioning design What are the parts of the electrical installation of cold storage engineering installation What are the performance advantages of air-cooled chillers What is the hazard of high temperature to compressor motor and lubricating oil What issues need to be considered in the construction of logistics warehouse cold storageWhat should I do if the refrigerator trips and leaks
Subscribe to relevant news content?
Subscription
Unsubscription
Recent related posts
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
US$2307.69
Panasonic Servo Motor MHMF022L1V2M
US$653.85
Honeywell Solenoid Valve VE4025B1045
US$334.62
ROTEN Mechanical Seal 8E5K-22-X
US$384.62
P+F Pepperl Fuchs Sensor NCB5-18GK40-N0
US$130.49
PIZZATO Switch FR 1193-D10M2
US$617.69
SUNON Fan EE80251S2-1000U-999
US$15.00
KCL Vane Pump VQ215-43
US$3418.46
BKD Bearing CRBC8016UU-P5
US$66.00
Copeland Compressor 2DL3F20K0-TFD-C00
Contact Us
SMC Solenoid Valve 10-SZ3160-5MOZD-C4
US$107.69
TOYOOKI Vane Pump HVP-FCE1-F17-50R-B
Contact Us
Ebmpapst Fan G3G108BB0102
Contact Us