Several methods of adding refrigerant for household central air-conditioning
Do you know how to add refrigerant to the central air conditioner? Let’s take a look with the editor today!
  1, observation method
Set the air conditioner to operate in the state of cooling or heating high-speed wind. When the amount of fluorine is correct, the temperature difference between the inlet and outlet of the indoor heat exchanger is 10cm: greater than 12°C during cooling, greater than 16°C during heating; indoors during cooling The heat exchanger has all condensation, the average low evaporation sound, condensation at the outdoor shut-off valve, continuous condensation and dripping in summer, and no frost or dew at the junction of the indoor heat exchanger and the capillary; when heating, the wall temperature of the indoor heat exchanger Above 40°C.
In actual maintenance, when the frequency conversion air conditioner has a high requirement for the correctness of the amount of fluorine, or the fixed frequency air conditioner needs to be vacuumed due to the refrigeration pipeline system, the quantitative fluoride method should be adopted. If the pipeline system needs to be supplemented with fluorine, it is appropriate Adopt the method of measuring current as the main, measuring gauge pressure as the supplement, and taking into account the observation. 
     2, quantitative fluoride
Connect the three-way valve, pressure gauge, fluorine hose, fluorine bottle or vacuum pump to the process port of the three-way stop valve. After fluorine is discharged and vacuumed, start to add fluorine slowly. Use a platform scale and other more accurate measuring tools to weigh, when The reduced amount of fluorine in the fluorine bottle is the standard fluorine amount on the nameplate of the air conditioner. When the fluorine bottle valve is closed. Baidu Ansheng HVAC, 20 years of service experience, a professional leader in central air conditioning for residential water systems in Hunan
  3, measuring current
Set the air conditioner in the cooling or heating high-speed wind state (the inverter air conditioner is set in the test operation state), and observe the change of the clamp ammeter while adding fluorine at the process port of the low-pressure shut-off valve. When it is close to the rated working current calibrated on the air conditioner nameplate When the value is set, the valve of the fluorine bottle is closed. At this time, let the air conditioner continue to operate for a period of time. When the room temperature is close to 27°C in the cooling state or the room temperature is close to 20°C in the heating state, the outdoor unit air temperature and the grid voltage are considered Factors of working current, while fine-tuning the amount of fluorine added to reach the rated working current value to achieve correct fluorine addition. The reason for the fine-tuning is that the rated working current value calibrated on the air conditioner nameplate is tested by the air conditioner manufacturer under the following conditions Data: Cooling status, fan high-speed wind at power supply voltage 220V or 380V, indoor air temperature 27℃, outdoor unit air temperature 35℃; heating status, fan high speed wind at power supply voltage 220V or 380V, indoor air temperature 20℃, outdoor unit The air temperature is 7°C. The fine-tuning data summarized in practice is: in the cooling state, the outdoor unit air temperature is 35°C as the scale, and the outdoor temperature increases or decreases by 1°C, and the rated operating current value is increased or decreased by 1.4%; heating state When the outdoor unit air temperature is 7℃ as the scale, the outdoor temperature increases or decreases by 1℃, increase or decrease 1% of the rated operating current value; in the cooling or heating state, the rated power supply voltage is 220V or 380V as the scale, Each time the power supply voltage increases or decreases by 1V, the rated operating current is reduced or increased.
   4. Pressure measurement method
Put the air conditioner in the cooling high-speed wind state (in winter, when heating needs to add fluoride, set the air conditioner in the forced cooling state or put the room temperature sensor in the warm water of about 27 ℃ to simulate the summer temperature to keep the air conditioner in the cooling state), At the process port of the low-pressure shut-off valve, observe the low pressure of the vacuum pressure gauge while adding fluorine. When the low pressure is 0.49MPa (in summer) or 0.25MPa (in winter), close the fluorine cylinder valve. Then consider the outdoor unit air temperature and indoor cooling load The size and other factors that affect the low pressure pressure, fine-tune the amount of freon and the gauge pressure, so as to add fluorine correctly. The reason for the fine-tuning is that the low pressure is directly proportional to the indoor cooling load, that is, the greater the cooling load, the higher the pressure, and vice versa. ;Because the fluorination process port and surrounding pipes are installed outdoors, their pressure and evaporation temperature are greatly affected by the outside temperature. The actual pressure and evaporation temperature of the indoor heat exchanger should be higher in summer and lower in winter. Summary in practice When the fan has high-speed wind and the indoor temperature is 27℃, the low-pressure pressure data is shown in the attached table.

Related Info
Reasons for the reduction of refrigeration equipment system cooling capacity Reasons for vibration of inlet and outlet pipes of reciprocating compressor Refrigeration system 41 essay questions, too comprehensive! Requirements for adding refrigerant to industrial chiller system Safety code for cold storage wire installationSeveral methods of adding refrigerant for household central air-conditioning
Subscribe to relevant news content? 
Subscription
 Unsubscription
Recent related posts
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
US$2307.69
 Panasonic Servo Motor MHMF022L1V2M
US$653.85
 Honeywell Solenoid Valve VE4025B1045
US$334.62
 ROTEN Mechanical Seal 8E5K-22-X
US$384.62
 MAC Solenoid Valve 45A-AC1-DDFJ-1KD
US$211.54
 Nachi Gear Pump IPH-2H-20
Contact Us
 Baumer Sensor UNAM 12P1914/S14D
US$590.84
 Omron Sensor EE-SPX402-W2A
US$80.50
 TPC Air Cylinder ADQB32-35DM-TH
Contact Us
 Copeland Compressor ZH40KCE-TEZ-650
Contact Us
 HENGSTLER Encoder RI58-O/400EK.43KB
Contact Us
 SMC Proportional Valve ITV3050-014S
Contact Us