Selection of cold storage electrical control system and other design considerations
The refrigeration electrical control system is a necessary condition to ensure that the cold storage always automatically works within the set range. Its main work flow includes:
  When the compressor works: the cold storage reaches the set temperature, and the compressor stops working. When the storage temperature rises to the set temperature, the compressor restarts to start refrigeration.
Automatic defrosting: Generally, the defrosting heating action is automatically started for about 6 hours. There are two control parameters for defrosting, one is time and the other is temperature. When one of the two conditions is reached, the defrosting process ends, and it takes 2 minutes after the end. Refrigerate after about the dripping time to make the temperature of the cold storage reach the required temperature as soon as possible. The cold storage design chooses Kuhua Refrigeration.
  Alarm function: A warning is issued when the temperature library exceeds the set requirements, so that it can be processed in time to ensure food safety.
  Safety requirements: The overall environment of the cold storage is relatively humid, and its surface is made of metal materials, which is prone to leakage. Therefore, the built-in electrical appliances in the cold storage body can use low-voltage equipment, such as lights, anti-condensation heating wires, etc.
Drainage: In the current design of small cold storage, air cooling is the main method (more and more cold storages are also water-cooled). The air cooler needs to be defrosted regularly to increase the heat exchange efficiency. Each cold storage should independently reserve a drainage position , Generally a PVC drainage pipe with a diameter of 50 is enough, located near the outside of the cold storage near the air cooler.
Exhaust air: Because small cold storage is generally installed indoors, the compressor matching is relatively small, considering the cooling loss, the compressor is generally near the cold storage, so the heat discharged by the cold storage may be in a certain narrow space, and exhaust air should be considered at this time , To ensure the proper condensing temperature of the compressor unit. The exhaust air volume should not be less than the exhaust air volume of the condenser of the compressor unit. Moisture-proof: The surface forming base plate of the cold storage is made of aluminum, color steel or galvanized sheet, and the cold storage is relatively humid due to the long-term low temperature, so it should be moisture-proof, especially the insulation material must not enter water, otherwise the insulation effect will not be good.

Related Info
Pay attention to these details. The air energy heat pump can be used for more than 10 years. Precautions for assembly of compressor oil scraper ring Principles and characteristics of heat recovery series air conditioning units Radiator heating system riser pipe installation and precautions Selection knowledge of screw chillerSelection of cold storage electrical control system and other design considerations
Subscribe to relevant news content? 
Subscription
 Unsubscription
Recent related posts
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
US$2307.69
 Panasonic Servo Motor MHMF022L1V2M
US$653.85
 Honeywell Solenoid Valve VE4025B1045
US$334.62
 ROTEN Mechanical Seal 8E5K-22-X
US$384.62
 HENGYI Vane Pump VD1-30F-A2
US$173.08
 Copeland Compressor CR28K6E-TF5-125
Contact Us
 TOSHIBA Electric Motor TD-80M-0.75-4KL
US$503.85
 ANSON Vane Pump IVPQ3-30A-F-L-86C-10
Contact Us
 Carmex Tool for Metal Cutting 22ER 6.0ISOMXC
Contact Us
 VBI Bearing 5217-RS
US$120.00
 Copeland Compressor 6DBXR32ME-TSK-250
Contact Us
 Suntronix Fan SJ4010
US$5.77