Responding to the failure of the air conditioning compressor in the computer room, one solution!

Responding to the failure of the air conditioning compressor in the computer room, one solution!

The special air conditioner for the computer room is designed based on the characteristics and requirements of the computer room and each communication room. It has the characteristics of constant temperature and humidity, high control accuracy, high air cleanliness and high reliability.

1. If there is moisture in the air-conditioning copper pipe system, it will affect the insulation effect of the air-conditioning compressor. Moisture, refrigerant and refrigerating oil circulate in the system, and through changes in conditions such as high temperature and low temperature, acidic substances are generated, which will affect the motor. Damage to the insulating layer. Under long-term operation, the air-conditioning compressor will be burned.

2.When the air conditioner compressor is started, there is generally a step-down starting circuit. When the temperature of the air conditioner is set improperly, the cooling temperature is too low, and the heating temperature is too high, the air conditioner compressor will be switched on and off frequently, which will shorten the life of the air conditioner compressor.

refrigeration compressor,compressor,Mitsubishi Compressor,Bristol Compressor,HITACHI Compressor,Danfoss compressor to solve the problem

3. When the air conditioner power supply voltage is too high or too low, it will affect the air conditioner compressor. When the long-term operation of the air-conditioning compressor is in a low-efficiency overheating condition, it will cause poor insulation.

3.The smart cloud box system is composed of the collection layer, the transmission layer and the management layer. Pangeotech's smart cloud box system is composed of various I/O acquisition and control modules and sensors, directly connected to various monitoring equipment, and collects on-site signals such as UPS, air conditioning, temperature and humidity, and water leakage.

refrigeration compressor,compressor,Mitsubishi Compressor,Bristol Compressor,HITACHI Compressor,Danfoss compressor to solve the problem refrigeration compressor,compressor,Mitsubishi Compressor,Bristol Compressor,HITACHI Compressor,Danfoss compressor to solve the problem

5. When the air conditioner compressor burns out, it will not only produce strong acid, but also will remain in the system. If it is not cleaned up, when the new air conditioner compressor starts to operate, the residual acid will corrode the insulating layer of the air conditioner compressor, causing the new air conditioner compressor to be burned.

6. In order to carry out more efficient operation, maintenance and management of important equipment in the computer room, Pangeo Technology has deployed a set of IoT monitoring system for the data center computer room, which can realize remote monitoring based on on-site monitoring. The web-side synchronization realizes centralized monitoring in different environments.

  7. When the cooling effect of the air-conditioning compressor is not good, there will be poor control of the return air of the air-conditioning system, the return air temperature is too high or the return air volume is low, resulting in insufficient cooling of the compressor coil.

   8. When the rolling parts of the air-conditioning compressor are stuck, if the maintenance action of the motor fails, the air-conditioning compressor will be burned due to overload.

   The computer room air-conditioning control system presents the air temperature and humidity and the operating status of the air-conditioning unit by the controller, analyzes the signals fed back by the sensors, and issues commands to the unit's various function items to achieve the effect of controlling the air temperature and humidity.