HVAC people collect these data, better than ten years of work experience!
HVAC people, we know that the HVAC project contains more systems, the situation is complicated, and most of the pipelines are hidden in the tube wells, walls, and ceilings, so the design process is very complicated, but don’t worry, we can step on the predecessors’ Go forward on your shoulders!
 
   Today, I will share the estimated value of an HVAC designer with years of work experience to everyone, so that your work will save time, effort and worry!
 
   1. Area estimation
 
   Refrigeration room: 1% of building area
 
   Boiler room: 1% area
 
   Public heat exchange station: 0.5% of building area
 
   Residential heat exchange station: 200m2/50,000 m2, 300m2/100,000 m2
 
  New fan room: 20m2
 
  Pressurized blower room: 15m2
 
   Heating small room: 12m2
 
   Ventilation and smoke exhaust machine room: 20m2
 
   2. Floor height estimation
 
   Boiler: Clear height 5m
 
   Heat Exchange Station: Net height 4m
 
   Centrifuge: Net height 5m
 
   Screw machine: Net height 4m
 
  Lithium Bromide: Net height 5m
 
   3. Load estimation
  Boiler room: 1500kg/m2, with vibration
 
   Heat exchange station: 1000kg/m2
 
  Cooling tower: 1000kg/m2
 
   Oil fume purification unit: 200kg/m2
 
   Floor heating: 120kg/m2
 
   4. Price estimation
 
  Ground source heat pump: 1,000 yuan/m2 building area
 
   Water ring heat pump: open cooling tower, 350 yuan/m2 building area
 
   Water ring heat pump: closed cooling tower, 400 yuan/m2 building area
 
   Air-cooled heat pump: 300 yuan/m2 building area
 
  Multiple connections: 350 yuan/m2 construction area
 
   5. Load estimation
’
   Heating estimate: 40w/m2 building area
 
   Heating estimate: 80w/m2 heating area
 
   Office: 180w/m2 air-conditioned area
 
  Meeting: 230w/m2 air-conditioned area
 
  Multi-function hall: 250w/m2 air-conditioned area
 
   Large dining: 250w/m2 air-conditioned area
 
  Small dining: 300w/m2 air-conditioned area

Related Info
What to do if the compressor of screw chiller is damaged Refrigeration principles of refrigerators and air conditioners Common problems and solutions of industrial chillers summarized by the maintenance master Failure Analysis of Air Conditioner Button Circuit Suggestions on safe and intelligent control of air conditioning and ventilation systems during epidemicsHVAC people collect these data, better than ten years of work experience!
Subscribe to relevant news content? 
Subscription
 Unsubscription
Recent related posts
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
US$2307.69
 Panasonic Servo Motor MHMF022L1V2M
US$653.85
 Honeywell Solenoid Valve VE4025B1045
US$334.62
 ROTEN Mechanical Seal 8E5K-22-X
US$384.62
 EPCOS Resistor B72220S271K502
Contact Us
 Schneider Circuit Breaker A9D91610
US$450.00
 LENORD BAUER Encoder GEL260-VN000500A003
US$2307.70
 Daikin Compressor JT95BC-V1L
US$519.23
 Bristol Compressor H23A263DBEX
Contact Us