Is it normal to see smoke from the outdoor unit during air conditioning heating in winter
In winter, when using air-conditioning for heating, the effect is either reduced or there is no hot air. I always feel that the heating effect is very poor! Many air conditioners are surrounded by snow. Can they be effective?
1. What is the main principle of air conditioning heating?
is mainly to absorb the heat in the air through the outdoor unit, and take the absorbed heat to the indoor unit through the refrigerant cycle in the pipeline. The work of the indoor unit provides heat to the room to increase the indoor temperature.
2. Why the colder the weather, the worse the heating effect?
is mainly because the colder the weather, the lower the outdoor environment temperature, the more difficult it is for the air conditioning heating to absorb the air heat from the outdoor air environment, resulting in a relatively poor heating effect. This is the normal attenuation value in winter.
3. During the heating process, why does the indoor unit stop air supply for a period of time, and then automatically turn on after a few minutes?
This is the air conditioner is defrosting, the indoor unit will stop working during the defrosting process, and will continue to work after the defrosting process.
When heating in winter, since the evaporation temperature of the outdoor unit heat exchanger (ie condenser) is lower than 0°C, the outdoor air flowing through the condenser will condense on the fins and form frost. The frost will affect the condenser replacement. The heating area and the circulation of air affect the heating effect of the air conditioner.
Using air conditioning in winter, the following conditions are normal:
1. Due to the continuous low temperature, frequent defrosting occurs when the outdoor temperature is lower than 0℃. Generally, the air conditioner defrosts every 45-50 minutes, and the defrosting time is about 5-15 minutes each time. The defrosting is more frequent in rainy and snowy weather. The relative humidity in the air is too high, which is normal;
2.When heating and defrosting, there will be water dripping at the bottom of the outer unit of the air conditioner. In this case, frost will form on the outer unit pipeline and condenser fins during heating. The air conditioner will automatically defrost after a certain period of time. When defrosting, the outdoor opportunity to smoke is normal defrosting (this smoke is not the other smoke, do not alarm), do not worry, this water is not leaking, it is air conditioning defrosting water, which is a normal phenomenon;
3. There is no hot air when the air conditioner is just turned on. (Don’t call out that the air conditioner is broken when there is no hot air.) This is because the air conditioner has added the function of “anti-cold wind protection" during heating. It takes about 3~8 minutes to turn on the hot air; the outdoor unit works first when it is turned on in winter. The indoor unit tube temperature reaches a certain temperature before the indoor unit fan motor starts to run.
4. In winter heating mode, the air deflector of the internal unit of the air conditioner should be adjusted to the downward direction, so that the hot air blows down from the air outlet, the heating effect of the room is faster (otherwise the hot air floats on the upper part of the house, and the height is less than 2m Can't feel); hot air is light, cold air is heavy. If the hot air can't drop down, it is difficult to feel the heat in the room, and the temperature felt by the human body is low, which directly feels that the heating effect of the air conditioner is poor.
5. In the heating mode, try to turn on the medium and low wind speed. The first time you use the electric auxiliary heating, you will smell a burnt smell, please don't panic, this phenomenon is normal. (Everyone who has just started using it will have a strong smell) After a while, the smell will disappear!
6. After the cabinet air conditioner has been used for a period of time, the home power supply trips. In this case, check whether the size of the air conditioner matches the size of the main power switch. For example, it is recommended to use an air switch above 63A (old The house, the new air conditioner, the wiring does not match, it is also normal).
7. For the first use after winter, first check whether the battery of the remote control is charged. If the remote control shows up after the full screen is displayed, the air conditioner cannot be turned on, please replace the battery. Please clean the filter of the air conditioner first to ensure With a large air volume and healthy breathing!
8. For cooling in summer, the air-conditioning drain is discharged from the drain pipe of the inner unit; in winter, the drain is drained from under the outer unit in heating mode.

Related Info
What kind of equipment is generally used in cold storage How to select the refrigeration equipment Is the refrigerant gas or liquid The 8 accessory usages that must be mastered when using computer room air conditioners! How to clean the precision air conditioner in the standby room? How to determine the demand for precision air conditionersIs it normal to see smoke from the outdoor unit during air conditioning heating in winter
Subscribe to relevant news content?
Subscription
Unsubscription
Recent related posts
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
US$2307.69
Panasonic Servo Motor MHMF022L1V2M
US$653.85
Honeywell Solenoid Valve VE4025B1045
US$334.62
ROTEN Mechanical Seal 8E5K-22-X
US$384.62
UNIVER Solenoid Valve CM-9640R
US$218.08
IWIS Industrial Chain 80 D-1
US$223.08
SAND Transmitter PT322B-M22-20MPa-152/460
Contact Us
BANDO Belt RIB ACE 6PK 2235
US$51.15
ULVAC Vacuum Pump PMB100D-MF9J1S7XXB1
Contact Us
Mitsubishi HMI GT1150-QBBD
US$12155.74
Schneider Contactor LC1D098B7C
US$90.38
Copeland Compressor ZB75KC-TWD-230
Contact Us
Schaeffler INA Bearing HK2816
US$9.20
CAT Piston Pump 2530E
US$2307.69