Key points for safe operation of refrigeration operators in large cold storage
The main points of safe operation are as follows:
  1, safe operation regulations
   Generally, safe operating procedures should be formulated for the machines and equipment of refrigeration equipment, and refrigeration operators must strictly abide by them to ensure safe production.
   2. Familiar with the entire refrigeration system
  The refrigeration operator must be familiar with the whole set of refrigeration process system diagrams of the factory (unit), and should be familiar with the names and specifications of the main equipment.
  3. The refrigeration operators in the computer room should achieve "four requirements", "four diligence" and "four timely".
  ① "Four essentials" must ensure safe operation, ensure warehouse temperature, reduce condensing pressure as much as possible, and fully develop
   play equipment cooling efficiency.
  ②"Four Qin": look at the instrument frequently, check the temperature of the machine, listen to the sound of the machine, and understand the warehouse in and out
  Happening.
  ③"Four in time": timely drain oil, timely flush frost, timely release air, and timely clean condenser scale.
  4, the valve opens slowly
  Various valves on machinery and equipment pipelines should be opened slowly when opening.
   5. Constant water
   During the compressor operation, the condenser must not cut off water (stop operation)
  6, the liquid level is maintained at the specified value
   The liquid level of the high-pressure reservoir shall neither exceed 80% nor less than 30%.
  7, protect
  When performing operations such as adding ammonia or draining oil to the refrigeration system, the refrigeration operator should wear rubber gloves and a gas-proof surface
   implements to prevent burns on hands and face.
   8. Avoid opening by mistake
   For the standby valve (regulation station, etc.) that is open to the atmosphere, the ammonia valve or the sewage (oil discharge) set in the quick freezing room
   valve, the hand wheel should be removed at ordinary times to avoid opening by mistake.
  9、Hang opening and closing signs
  In order to avoid misoperation, the position and purpose of each control valve of the regulating station should be marked, and the handwheel of each valve should be
   open and close cards.
   10. Make a record
   The operation and maintenance of the compressor shall be recorded in a timely and correct manner.

Related Info
About inverter air conditioner fault repair skills Must know! Safe operation of refrigeration valves How to fix Samsung air conditioner failure Principle analysis of monitoring system for cold and heat source equipment What are the specific operation methods for maintenance of screw compressors in cold storageKey points for safe operation of refrigeration operators in large cold storage
Subscribe to relevant news content? 
Subscription
 Unsubscription
Recent related posts
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
US$2307.69
 Panasonic Servo Motor MHMF022L1V2M
US$653.85
 Honeywell Solenoid Valve VE4025B1045
US$334.62
 ROTEN Mechanical Seal 8E5K-22-X
US$384.62
 Inovance Servo Drive IS620MT5R4I-M
Contact Us
 HAYIGONG Tool for Metal Cutting Φ51-53
US$234.62
 Omron VFD Frequency Converter 3G3MV-A2007
Contact Us
 Bitzer Compressor 4PES-10Y-40P
Contact Us
 TOYOOKI Vane Pump HVP-FEE1-F75-75L-B
Contact Us
 IRC Resistor 1W 578K
US$19.23
 AMB VFD Frequency Converter AMB100-030P-T3
US$1730.77
 AirTAC Air Cylinder SILF40X150S
US$74.62
 Mean Well Power Supply GS280A24-C4P
US$166.93