How high does the family multi-connected central air conditioner ceiling need to be
The reason why many people choose home central air conditioners may be that they look more beautiful and will not spoil the decoration effect of the whole home. Yes, the central air-conditioning mainframes with "hiding" as the beauty are installed concealed in the ceiling of the ceiling, so the internal unit must be installed before the decoration. So, what are the requirements for the height of the ceiling when installing a home central air conditioner? How high should the central air-conditioning installation ceiling be controlled? Let's take a look with the editor!
  The height of the central air-conditioning ceiling should be determined according to the following factors:
  1, the height of the central air conditioner
   There is no definite value for the height of the central air conditioner internal unit. The height of the internal unit of different brands and different parameters is different. For example, the height of the Panasonic central air conditioner home internal unit is 200mm, which is very compact and saves installation space!
  2, central air conditioning drainage space
   This is mainly related to the drainage slope. The central air conditioner will produce a certain amount of condensate when it is running. In order to drain the accumulated water naturally and smoothly, the drainage slope of the household central air conditioner is generally 2-3 cm, which can be determined according to the model and design plan.
   3. Central air-conditioning duct thickness
  The thickness of the central air-conditioning duct mainly depends on the quality of the auxiliary materials. Generally, the duct length requires the thicker the duct.
  4, installation reserved space
When installing the indoor unit, there is a motor inside the central air conditioner. During operation, the internal machine will vibrate slightly as the motor is turned on. In order to reduce the noise generated by resonance and protect the compressor from running well, it needs to be placed on the ceiling of the central air conditioner. IQ reserves a certain amount of space, generally about 2 cm.
   5. Install condensate pump
   When the central air conditioner internal unit is running, a certain amount of condensate will be generated. There is a condensate drain pan at the bottom of the indoor unit, and the accumulated water will be drained into the room through the condensate pipe to avoid ceiling leakage. Because the condensate pipe interface is at the bottom of the internal unit, and the drain of the condensate pipe requires a certain slope, when the drainage distance is too long, the condensate pipe may drop higher than the space between the bottom of the internal unit and the ceiling, thus causing the ceiling of the central air-conditioning ceiling to drop. Therefore, in the case of insufficient ceiling, it is generally recommended to follow a drain pump to drain the condensate naturally.
In addition to the height of the indoor unit, the ceiling of the home central air conditioner is closely related to the construction process of the central air-conditioning installation company. Therefore, you must choose a regular home central air-conditioning company. The design of pipes and drainage slopes will be more standardized. Reasonably, the installer will make the pipeline as close to the wall as possible, and can also reduce the thickness of the ceiling, so as not to affect the aesthetics of the overall decoration.

Related Info
Chilled water flow measurement techniques for chillers Daily maintenance method of precision air conditioner for computer room Detailed explanation of multi-line air conditioning installation 3 times 5 key 8 steps specification Four methods to detect air conditioner noise How do you see the power of the air conditioner Air conditioning horse number and areaHow high does the family multi-connected central air conditioner ceiling need to be
Subscribe to relevant news content? 
Subscription
 Unsubscription
Recent related posts
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
US$2307.69
 Panasonic Servo Motor MHMF022L1V2M
US$653.85
 Honeywell Solenoid Valve VE4025B1045
US$334.62
 ROTEN Mechanical Seal 8E5K-22-X
US$384.62
 ARK Air Cylinder KAND20-25-I-P-A
US$49.23
 CAMOZZI Air Cylinder 24N2A20A330
Contact Us
 SHAKO Air Cylinder ICB50C600
US$166.39
 CDE Capacitor 940C16P22K-F
Contact Us
 Emerson Alco Expansion Valve TIH-B28 802729M
Contact Us
 Keyence Sensor GS-51N10
US$1133.90
 Neuma Solenoid Valve NVSC-7532M-D6-1
Contact Us
 SUNX Sensor NA2-N28-PN
US$1380.00
 TECO Servo Motor TSC08301C3BY3
Contact Us
 Suntronix Fan SJ1238HA1
US$93.33