Factors that must be considered in the design of multi-line central air conditioning
The purpose of the multi-line central air-conditioning design is to deal with excess heat and to provide a comfortable living environment. The heat that causes discomfort to the human body mainly includes: heat introduced through the enclosure structure, solar radiation heat entering through external windows, human body heat dissipation, lighting heat dissipation, heat dissipation from other internal heat sources such as equipment, food or material Heat dissipation, heat brought in by penetrating air, and latent heat generated by various moisture dissipation processes. The purpose of central air-conditioning is to remove the heat that causes indoor heating and discomfort for the human body. This heat is related to the structure of the house and the performance of the equipment, but what factors should we consider when replacing it in the design?
   1. The geographical location of the project
  The temperature in spring is changeable, the temperature in autumn drops sharply, the winter is cold and the summer is very hot, the severe cold period is short, and the summer heat period is long
   2. Room orientation
  The load of the westward room should be increased appropriately (cooling load: West>East>South>North)
   Three, the height of the house
   If the storey height is more than 5 meters and empty, the load needs to consider the additional height (1 meter increase 20w/m2)
   Fourth, the heat gain of the building
  The inner area generally has 10-20w/m less load than the outer area room, the basement generally has 15-20w/m less load than the outer area room, and the top floor generally increases 20-30w/m2
   5. Whether to consider heat exchange in winter
   When there is a demand for heating in winter, a unit with EVI function is recommended
   6. Multi-line central air-conditioning system pipe length
   The pipeline is too long, consider the pipe length correction, increase the unit load
   Seven, super ratio
  When over configuration, the load is not less than the normal value
   8. Remote indoor unit distance
  The most remote indoor unit close to the pipe length application requirement, increasing the unit load.

Related Info
Common problems during debugging of refrigeration and air conditioning systems Component maintenance method of water-cooled chiller Cooling method of water-cooled chiller Daily maintenance of chillers and emergency treatment Eight aspects allow the chiller to achieve energy saving in managementFactors that must be considered in the design of multi-line central air conditioning
Subscribe to relevant news content? 
Subscription
 Unsubscription
Recent related posts
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
US$2307.69
 Panasonic Servo Motor MHMF022L1V2M
US$653.85
 Honeywell Solenoid Valve VE4025B1045
US$334.62
 ROTEN Mechanical Seal 8E5K-22-X
US$384.62
 Copeland Compressor ZH45KCE-TFD-871
Contact Us
 SKF Bearing NU 316 ECM
US$569.23
 Ebmpapst Fan RER190-39/18/2T
Contact Us
 Copeland Compressor 4DN3-1000-TSK-201
Contact Us
 Mean Well Power Supply HLG-600H-30A
US$331.00
 IVZ Bearing UC216
US$38.46
 PIZZATO Switch FG 60DD7D0C-F28
US$615.38
 VTOZ Proportional Valve MA-RZMO-A-010/50/X10
Contact Us
 BOHLER Welding Wire B?HLER DCMS-IG
US$33.38