The quality of the cooling medium affects the cooling effect of industrial chillers
After enterprises purchase industrial chillers, when the cooling performance of industrial chillers decreases during operation, many enterprises think that it is related to the failure of industrial chillers. In fact, this is not the case. Most of the time, the failure of industrial chillers with low cooling efficiency is not caused by malfunctions, but due to insufficient refrigerant or poor refrigerant quality in industrial chillers. Due to the large gap between the cooling media of different types of industrial chillers, in the process of using industrial chillers, it is necessary to regularly check whether the cooling media can be used normally, so as to avoid a simple refrigerant loss failure and cause serious decline in the cooling performance of the equipment.
According to the cooling mode of the equipment, there are many types of cold media. When using industrial chillers, the editor of okmarts.com recommends that companies formulate suitable inspection plans in time, and carefully focus on the refrigerants of industrial chillers within the scheduled inspection time. Inspection. If the refrigerant is missing or leaking, it needs to be dealt with in time. The more timely the treatment, the higher the operating safety factor of the equipment, so as to prevent the industrial chiller from being affected by the quality of the cold medium and causing serious decline in cooling performance. So how to judge whether the cold medium quality is normal?
1. When judging whether the quality of the cooling medium is normal, it can be judged according to the amount of energy consumption for cooling and the waiting time for cooling. If the cooling time is longer and the amount of energy consumption increases significantly, it means that the industrial chiller is faulty or the refrigerant Serious missing problems need to be dealt with by the enterprise in time to avoid affecting the normal use of industrial chillers.
2. When the equipment cannot meet the company's requirement for lowering the space temperature in a unit of time, the company needs to be aware of possible problems with the refrigerant, instead of blindly detecting faults for industrial chillers. Due to the continuous innovation in the production technology of industrial chillers, basically the probability of failure of industrial chillers is low. Equipment analysis from the perspective of refrigerant can save valuable inspection time and ensure that enterprises can quickly restore the industrial chillers in the shortest time. run.
Whether the cold medium quality is sufficient and stable directly affects the cooling performance of industrial chillers. In order to better use industrial chillers, companies need to timely detect whether the industrial chiller refrigerant is sufficient during the process of operating industrial chillers. Only sufficient refrigerant can ensure that the equipment quickly reduces the space temperature and prolongs the service life of the equipment. Conditions to prevent enterprises from affecting the normal completion of production tasks due to refrigerant problems.

Related Info
The function and selection method of throttling capillary in industrial chiller The function and setting of the oil trap in the refrigeration system The heat pump is prone to frost between +4~-4℃. The symptoms and reasons are not beyond these 10 points. The main difference between the appearance of the evaporator and the condenser The most basic maintenance skills for air conditioner failureThe quality of the cooling medium affects the cooling effect of industrial chillers
Subscribe to relevant news content?
Subscription
Unsubscription
Recent related posts
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
US$2307.69
Panasonic Servo Motor MHMF022L1V2M
US$653.85
Honeywell Solenoid Valve VE4025B1045
US$334.62
ROTEN Mechanical Seal 8E5K-22-X
US$384.62
Dwyer Transmitter 636D-7-LP
US$1679.00
MURATA Resistor POT3106W-1-105
Contact Us
OSHON Vane Pump VPE-F24-B-10
Contact Us
Mitsubishi HMI GT1030-HBD2-C
US$576.92
Copeland Compressor ZR42K5-TFJ
Contact Us
Neuma Solenoid Valve NVA-7521-RA-5L
Contact Us
Honeywell Expansion Valve TLK-00012
Contact Us
Ebmpapst Fan R3G250-RE07-05
Contact Us