Key points for safe operation of large-scale cold storage refrigeration operators
The main points of safe operation are as follows:
  1, safe operation regulations
   Generally, there should be safety operating procedures for the machines and equipment of refrigeration installations, and refrigeration operators must strictly follow them to ensure safe production.
   2. Familiar with the entire refrigeration system
  The refrigeration operator must be familiar with the whole set of refrigeration process system diagrams of our factory (unit), and should be familiar with the names and specifications of the main equipment.
  3. The refrigeration operators in the computer room should achieve "four requirements", "four diligence" and "four timely".
  ① "Four essentials" must ensure safe operation, ensure warehouse temperature, reduce condensing pressure as much as possible, and fully develop
   Improve the cooling efficiency of the equipment.
  ②"Four Qin": look at the instrument frequently, check the temperature of the machine, listen to the sound of the machine, and understand the warehouse in and out
  Happening.
  ③"Four in time": timely drain oil, timely flush frost, timely release air, and timely clean condenser scale.
   4, the valve opens slowly
  Various valves on machinery and equipment pipelines should be opened slowly when opening.
   5. Constant water
   When the compressor is running, the condenser must not be cut off (stop running)
  6, the liquid level is maintained at the specified value
   The liquid level of the high-pressure reservoir shall neither exceed 80% nor less than 30%.
  7, protect
  When performing operations such as adding ammonia or draining oil to the refrigeration system, the refrigeration operator should wear rubber gloves and a gas-proof surface
   tool to prevent burns on hands and face.
   8. Avoid opening by mistake
   For the standby valve (regulation station, etc.) that is open to the atmosphere, the ammonia valve or the sewage (oil discharge) set in the quick freezing room
   valve, the hand wheel should be removed at ordinary times to avoid opening by mistake.
  9, hanging up and closing signs
  In order to avoid misoperation, the position and purpose of each control valve of the regulating station should be marked, and the handwheel of each valve should be
   Open and close cards.
   10. Make a record
   The operation and maintenance of the compressor should be recorded in a timely and correct manner.

Related Info
How to properly use central air conditioning during the epidemic Just read this one How to solve the air conditioner failure HVAC people collect these data, better than ten years of work experience! Ice machine installation and commissioning guidelines and installation service process Is the refrigerant gas or liquidKey points for safe operation of large-scale cold storage refrigeration operators
Subscribe to relevant news content? 
Subscription
 Unsubscription
Recent related posts
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
US$2307.69
 Panasonic Servo Motor MHMF022L1V2M
US$653.85
 Honeywell Solenoid Valve VE4025B1045
US$334.62
 ROTEN Mechanical Seal 8E5K-22-X
US$384.62
 Bristol Compressor H73B28QDBEB
Contact Us
 SKF Bearing 71917 CD/HCP4A
US$501.60
 DINE Tool for Metal Cutting FBB26N-C
US$127.69
 Speck Water Pump VG-95
US$355.77
 YUKEN Vane Pump VPVQQ-PSAO-05C-PSAW-05EA-60
Contact Us
 Copeland Compressor 3DS3R17ML-TFC-201
Contact Us
 SKF Bearing 16064/C3
US$2423.08
 PIZZATO Switch FK 3456-XM1V38
US$576.92
 Ebmpapst Fan 9274014841
Contact Us