Installation process of ground source heat pump heat exchanger
If the machine works for a long time, it will get hot, because once the machine works, it will do work, and the work will naturally generate a lot of heat. If this heat is not released in time, it is likely to damage the machine. Therefore, a heat exchanger device is installed on the ground source heat pump equipment. For the installation of ground source heat pump heat exchangers, we can refer to the following methods:
The heat exchangers are installed in series or in parallel. There are two types of loops for fluid flow in ground source heat pump heat exchangers: series and parallel. The series system has a larger pipe diameter and higher pipeline costs, and the length and pressure drop characteristics limit the system capacity. Parallel systems have smaller pipe diameters, lower pipeline costs, and are often arranged in the same pattern. When the flow of each parallel loop is balanced, the heat exchange rate is the same, and its pressure drop characteristics are beneficial to improve the system capacity. Therefore, the actual project generally uses the same program in parallel.
pipe selection. Generally speaking, once the heat exchanger is buried in the ground, it is basically impossible to repair or replace it. This requires that the chemical properties of the buried underground pipes are stable and corrosion resistant. The metal pipes used in conventional air-conditioning systems have serious shortcomings in this regard, and there are more pipes that need to be buried underground, and lower-priced pipes should be given priority. Therefore, plastic pipes are generally used in ground source heat pump systems.
Determine the pipe diameter. In actual engineering, two requirements must be met to determine the pipe diameter: (1) The pipe should be large enough to maintain the minimum transmission power; (2) The pipe should be small enough to maintain turbulent flow in the pipe to ensure the transmission between the fluid and the inner wall of the pipe. heat. Obviously, the above two requirements contradict each other and need to be considered comprehensively. Generally, a small pipe diameter is used for the parallel loop, and a large pipe diameter is used for the header.
The installation process of the ground source heat pump heat exchanger must be followed, otherwise, it will affect the later use on the one hand and be prone to failure, on the other hand, it will also have a lot of impact on the construction.

Related Info
How to clean the return air duct of central air conditioning How to deal with the failure of the freezer to start How to make the service life of ground source heat pump air conditioner longer How to recover refrigerant Industrial chiller fault code corresponding fault description and operationInstallation process of ground source heat pump heat exchanger
Subscribe to relevant news content?
Subscription
Unsubscription
Recent related posts
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
US$2307.69
Panasonic Servo Motor MHMF022L1V2M
US$653.85
Honeywell Solenoid Valve VE4025B1045
US$334.62
ROTEN Mechanical Seal 8E5K-22-X
US$384.62
SIEMENS Capacitor Z113515296
US$6.46
BANDO Belt STS S2M-204-200
US$65.35
Festo Solenoid Valve MHA2-MS1H-5/2-2
US$162.23
Omron Switch WLCA2-LD
Contact Us
Copeland Compressor RR81C2E-IAV-099
Contact Us
Copeland Compressor ZPD91KCE-TF3-275
Contact Us
Suntronix Fan SWQ133
US$107.69