How to use refrigerant to empty the air conditioner after installation
Air, the moisture and impurities contained in the air in the air conditioner system will cause increased pressure, increased current, increased noise, increased power consumption, etc., which will reduce the cooling (heat) capacity, and may also cause ice blockage and dirty blockage. Wait for failure.
At present, the air discharged from the indoor unit and pipeline is mostly ejected by the outdoor unit refrigerant:
01) Open the air pipe connecting the pipeline between the indoor unit and the outdoor unit;
02) Use a hexagon wrench to open the two-way stop valve on the outdoor unit to ensure that the refrigerant can enter the indoor unit pipeline;
03) As the refrigerant slowly enters the indoor unit pipeline, the refrigerant gradually occupies the pipeline, ejects the gas in the indoor unit pipeline, and discharges it from the opening of the disconnected thick pipe (trachea);
04). When the refrigerant is seen to be discharged, quickly connect the air pipe to the three-way shut-off valve, tighten the holder, and the exhaust operation is completed.
Note:
1) The 30s exhaust time mentioned here is just a reference value. In actual operation, you must control the exhaust time by feeling whether the sprayed gas becomes cold or not.
2) Mastering the exhaust time is very important for the use of air conditioners, because the exhaust time is too long, the refrigerant in the refrigeration system will be excessively lost, which will affect the cooling effect of the air conditioner; the exhaust time is too short, The air in the indoor unit and pipeline is not exhausted, which will also affect the cooling effect of the air conditioner.
3) Inverter air conditioners must be evacuated by vacuuming, because this type of air conditioner mostly uses R410a refrigerant. This refrigerant is mixed in strict accordance with a certain ratio. If part of the gas is discharged by the headspace method, the ratio of the refrigerant will change and affect the refrigeration effect (after about one year of use, the effect on the refrigeration effect is obvious). The refrigerant headspace method is adopted.

Related Info
Honeywell Connected People Solution Helps Wood Group Ensure Business Continuity How can humidification and refrigeration equipment companies reduce their operating costs and improve efficiency through CRM systems How long is the service life of the refrigerator How to switch freely between cooling, heating and dehumidification modes How to use cold storage management system in cold chain enterprisesHow to use refrigerant to empty the air conditioner after installation
Subscribe to relevant news content?
Subscription
Unsubscription
Recent related posts
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
US$2307.69
Panasonic Servo Motor MHMF022L1V2M
US$653.85
Honeywell Solenoid Valve VE4025B1045
US$334.62
ROTEN Mechanical Seal 8E5K-22-X
US$384.62
Schneider Circuit Breaker OSMC32N2C3
Contact Us
COSEL Power Supply CHS2004812-R
US$401.73
Parker Sporlan Expansion Valve 108703
Contact Us
KCL Vane Pump VPKCC-F1212-A1A1
US$557.69
HIWIN Linear Guideway MGW9C2R260Z0H
Contact Us
Banner Sensor VS2KAN5V
US$134.63
BANDO Belt STS S3M-735-200
US$214.12
LOWARA Water Pump 10SV08F030T
US$2115.38
COSEL Power Supply PBA75F-3R3-C
US$313.46