Do you know what problems the chiller is prone to encounter
When we use the chiller every day, what problems are easy to encounter? how should I solve this? Let’s take a closer look with the editor of okmarts.com today!
1. The reason why the chiller can't refrigerate
1. The filter is blocked. When the filter is blocked, the dust on the condenser will accumulate, which will affect the cooling effect of the refrigeration equipment over time. If things go on like this, it may even cause refrigeration equipment to fail.
Solution: Clean the filter regularly or irregularly.
2. The content of coolant is low. If the content of coolant is too small, the equipment will not be able to absorb oil and the cooling effect will be reduced.
Solution: Check the coolant frequently to see if the coolant level is maintained between high and low, and add coolant in time when the coolant is too low.
3. Lack of Freon. In some early refrigeration equipment using Freon as a refrigerant, Freon will volatilize after a long time of use, thereby affecting the cooling effect.
Solution: Poly Refrigeration reminds you that Freon may be harmful to the human body, so in this case, you should find a professional maintenance company to add it.
4. The power supply voltage is low or the power of the refrigeration equipment is not enough.
2. How to judge the lack of fluoride in the chiller?
The main manifestations are low fluorine pressure, decrease in cooling capacity, increase in return air temperature, increase in exhaust temperature, or naturally look at the evaporation pressure, if it can’t be cooled down, and the evaporation pressure is very low, it is naturally wrong if it is lower than 2-3kg , It is necessary to doubt whether it is missing, but it may also be caused by other reasons. Also, after stopping for a long time and starting the machine, the evaporation pressure quickly drops from the corresponding temperature to 2-3.
3. What type of refrigerant is generally added to industrial chillers?
Now if there is no special requirement, the chiller refrigerant is HCFC-22, which is R22, and its boiling point is -41 degrees. Physical and chemical properties: R22 (Freon22, Chlorodifuoromethane), molecular formula CHClF2, molecular weight 86.47. R-22 is a colorless, almost odorless gas at room temperature, non-combustible, non-corrosive, and minimally toxic. It can be liquefied into a colorless and transparent liquid under pressure. It is an HCFC refrigerant. Main use: Freon-22, molecular formula: CHClF2, molecular weight: 86.47. R-22 is widely used in household air conditioners, central air conditioners and other commercial refrigeration equipment; it can also be used as a raw material for polytetrafluoroethylene resin and an intermediate for fire extinguishing agent 1121.
4. What should I do if frost occurs during the operation of the chiller? How to solve?
1. Check whether the amount of refrigerant is within the standard range. Regardless of whether it is charged too much or too little, it will affect the normal operation of the chiller.
2. Are multiple chillers used in parallel? If the number of units to be turned on is large, check whether it is caused by the excessively long start-up time of the frosting unit (the combined unit has a control panel that can set the start and stop time of each chiller as required).
3. If it is a chiller, please check whether the opening of the expansion valve is too large. The small point can be fine-tuned (if it is an electronic expansion valve adjustable circuit control panel).
4. If the opening of the expansion valve is too small or clogged, the amount of refrigerant supply will decrease, which will make the evaporation temperature low, causing frost on the evaporator fins; if the refrigerant does not evaporate and flow back Continued evaporation in the air pipe and compressor will cause frost on the compressor and return pipe.
5. Check whether the filter is too dirty or the evaporator fins are too dirty, which makes the heat exchange effect poor, and the refrigerant evaporates and flows back to the return pipe and the compressor to continue to evaporate and cause frosting.
6. If the operating environment of the chiller is not good, or the air is not circulating, it will also cause poor heat dissipation and affect the frosting of the unit.
If the chiller has a frost failure, the company must use professional methods to complete the troubleshooting in time to ensure the safe and stable operation of the chiller, and regularly check whether the various parts of the chiller are worn or damaged, and should be replaced in time. In addition, when companies purchase water chillers, they should match the water chillers reasonably according to production needs, so as to better use the chillers and reduce the cost of use of the company.

Related Info
Common sense of home appliances how to use an air conditioner for ten years Common sense of home appliances the correct posture for adding fluoride to air conditioners Daily maintenance and maintenance methods of ground source heat pumps Daily maintenance and performance characteristics of air-cooled chillers Debugging method of central air conditioning systemDo you know what problems the chiller is prone to encounter
Subscribe to relevant news content?
Subscription
Unsubscription
Recent related posts
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
US$2307.69
Panasonic Servo Motor MHMF022L1V2M
US$653.85
Honeywell Solenoid Valve VE4025B1045
US$334.62
ROTEN Mechanical Seal 8E5K-22-X
US$384.62
Copeland Compressor ZRT96KCE-TFD-930
Contact Us
Kompass Vane Pump T6CC-031-010-1R00-B1
Contact Us
Ebmpapst Fan R2E250-AL27-17
Contact Us
Copeland Compressor 4DR1R28M0-TSE-001
Contact Us
AirTAC Air Cylinder MAC40X70SCA
US$45.62
YINGB Light Curtain NA1-88
Contact Us
Schneider Servo Motor BMH1402P17F2A
US$5308.46
Suntronix Fan SWQ16060
US$1169.23