| Type | 3RV2 |
| Breaker Type | Motor Protection Circuit Breakers |
| Rated current | 84 |
| Number of Poles | 1 pole |
| Setting range for thermal overload releases | 65...84 A |
Circuit breaker size S3 for motor protection, Class 20 A-release
65...84 A N-release 1170 A screw terminal Increased switching
capacity 100 kA
product brand name SIRIUS
product designation Circuit breaker
design of the product For motor protection
product type designation 3RV2
General technical data
size of the circuit-breaker S3
size of contactor can be combined company-specific S3
product extension
auxiliary switch Yes
power loss W for rated value of the current
at AC in hot operating state 34?W
at AC in hot operating state per pole 11.3?W
insulation voltage with degree of pollution 3 at AC
rated value
1?000?V
surge voltage resistance rated value 8?kV
maximum permissible voltage for safe isolation
in networks with grounded star point between
main and auxiliary circuit
400?V
protection class IP
on the front IP20
of the terminal IP00
shock resistance
acc. to IEC 60068-2-27 25g / 11 ms Sinus
mechanical service life (switching cycles)
of the main contacts typical 25?000
of auxiliary contacts typical 25?000
electrical endurance (switching cycles)
typical 25?000
reference code acc. to DIN EN 81346-2 Q
Ambient conditions
installation altitude at height above sea level
maximum
2?000?m
ambient temperature
during operation -20?...?+60?degrees centigrade
during storage -50?...?+80?degrees centigrade
during transport -50?...?+80?degrees centigrade
temperature compensation -20?...?+60?degrees centigrade
relative humidity during operation 10?...?95?%
Main circuit
number of poles for main current circuit 3
adjustable pick-up value current of the currentdependent overload release
65?...?84?A
operating voltage
rated value 690?V
at AC-3 rated value maximum 690?V
operating frequency rated value 50?...?60?Hz
operating current rated value 84?A
operating current
at AC-3
at 400 V rated value 84?A
operating power
at AC-3
at 230 V rated value 22?000?W
at 400 V rated value 45?000?W
at 500 V rated value 55?000?W
at 690 V rated value 75?000?W
operating frequency
at AC-3 maximum 15?1/h
Protective and monitoring functions
product function
ground fault detection No
phase failure detection Yes
trip class Class 20
design of the overload release thermal
operational short-circuit current breaking capacity
(Ics) at AC
at 240 V rated value 100?kA
at 400 V rated value 50?kA
at 500 V rated value 5?kA
at 690 V rated value 3?kA
maximum short-circuit current breaking capacity (Icu)
at AC at 240 V rated value 100?kA
at AC at 400 V rated value 100?kA
at AC at 500 V rated value 10?kA
at AC at 690 V rated value 6?kA
response value current
of instantaneous short-circuit trip unit 1?170?A
UL/CSA ratings
full-load current (FLA) for three-phase AC motor
at 480 V rated value 84?A
at 600 V rated value 84?A
yielded mechanical performance hp
for single-phase AC motor
at 110/120 V rated value 7.5?hp
at 230 V rated value 15?hp
for three-phase AC motor
at 200/208 V rated value 25?hp
at 220/230 V rated value 30?hp
at 460/480 V rated value 60?hp
at 575/600 V rated value 75?hp
Short-circuit protection
product function short circuit protection Yes
design of the short-circuit trip magnetic
Installation/ mounting/ dimensions
mounting position any
mounting type screw and snap-on mounting onto 35 mm standard mounting rail
according to DIN EN 60715
height 165?mm
width 70?mm
depth 176?mm
Ask questions
(0/1,200)
- Q: Can I request a specific delivery date for my order?
A: While we strive to deliver orders promptly, specific delivery date requests may not always be possible due to logistics and carrier limitations. However, if you have a specific requirement or need expedited shipping, please contact our customer service, and we will do our best to assist you.
- Q: What should I do if I forgot my password?
A: If you forgot your password, click on the "Forgot Password" link on the login page. Follow the instructions to reset your password.
- Q: Do you offer free shipping?
A: We may offer free shipping on select products or as part of promotional campaigns. You can check the product details or promotions to see if free shipping is available.
Reviews
- J
Jacquie Kill
Jun 27, 2025
Siemens Circuit Breaker 3RV2042-4RB10Super seller, thanks for the excellent service!HelpfulUnhelpful - M
Mike Kendrick
Sep 25, 2024
Siemens Circuit Breaker 3RV2042-4RB10You're a master for the quality parts!HelpfulUnhelpful - C
Carla Vicenti
Sep 12, 2024
Siemens Circuit Breaker 3RV2042-4RB10I'm glad I don't have to struggle with this website.HelpfulUnhelpful - C
Christopher Sobetski
Jan 21, 2024
Siemens Circuit Breaker 3RV2042-4RB10Thank You!HelpfulUnhelpful - A
Anonymous user
Nov 25, 2022
Siemens Circuit Breaker 3RV2042-4RB10All was ok! No problems whatsoever.HelpfulUnhelpful
Siemens Circuit Breaker 3RV2042-4RB10
✔ In Stock (Can ship in 5-7 days)

Online Support 24/7
12 Months Warranty for New Products
30 Days Money Back Guarantee
People who bought this item also viewed
Siemens Circuit Breaker 5SL6332-8CC
Siemens Circuit Breaker 5SY7514-7CC
Siemens Circuit Breaker 5SY7625-7CC
Siemens Circuit Breaker 5SY7403-7CC
Siemens Circuit Breaker 3WT8060-5UG04-5AB1
Siemens Circuit Breaker 5SY7406-7CC
AEG Circuit Breaker ELFA-E81-C3
Fuji Circuit Breaker EW32AAG-2P10A
CHINT Transformer BKC-100
Schneider Contactor LC1E1801B5N
CITEL Surge Protection Device DS41S-320
Aupo Fuse A0-5A-F
UniOhm Resistor 1210W3J0152T5E
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
LG LS Contactor 1255003700 GMD-32 DC12V
Leuze Sensor HT25CL1/2N-200-M12
B&R PLC INPUT MODULE X20CM8281
CKD Air Cylinder SCPG2-L-CB-10-25-P4
Kompass Vane Pump 50T+50T-39+14-LR
COKERY Belt 380J
Ebmpapst Fan R1G175-RB33-10