✔ In Stock (Can ship in 5-7 days)

Online Support 24/7
12 Months Warranty for New Products
30 Days Money Back Guarantee
| Type | 3RV2 |
| Breaker Type | Motor Protection Circuit Breakers |
| Rated current | 12 |
| Number of Poles | 1 pole |
| Setting range for thermal overload releases | 9...12 A |
Circuit breaker size S0 for motor protection, CLASS 10 A-release
9...12 A N-release 163 A screw terminal Switching capacity 30 kA at
600 V according to UL/CSA
product brand name SIRIUS
product designation Circuit breaker
design of the product For motor protection
product type designation 3RV2
General technical data
size of the circuit-breaker S0
size of contactor can be combined company-specific S00, S0
product extension
auxiliary switch Yes
power loss W for rated value of the current
at AC in hot operating state 9.25?W
at AC in hot operating state per pole 3.1?W
insulation voltage with degree of pollution 3 at AC
rated value
690?V
surge voltage resistance rated value 6?kV
maximum permissible voltage for safe isolation
in networks with grounded star point between
main and auxiliary circuit
400?V
protection class IP
on the front IP20
of the terminal IP20
shock resistance
acc. to IEC 60068-2-27 25g / 11 ms
mechanical service life (switching cycles)
of the main contacts typical 100?000
of auxiliary contacts typical 100?000
electrical endurance (switching cycles)
typical 100?000
reference code acc. to DIN EN 81346-2 Q
Main circuit
number of poles for main current circuit 3
adjustable pick-up value current of the currentdependent overload release
9?...?12.5?A
operating voltage
rated value 690?V
at AC-3 rated value maximum 690?V
operating frequency rated value 50?...?60?Hz
operating current rated value 12.5?A
operating current
at AC-3
at 400 V rated value 12.5?A
operating power
at AC-3
at 690 V rated value 7.5?kW
operating frequency
at AC-3 maximum 15?1/h
Auxiliary circuit
number of NC contacts for auxiliary contacts 0
number of NO contacts for auxiliary contacts 0
number of CO contacts
for auxiliary contacts 0
Protective and monitoring functions
product function
ground fault detection No
phase failure detection Yes
trip class CLASS 10
design of the overload release thermal
operational short-circuit current breaking capacity
(Ics) at AC
at 690 V rated value 4?kA
maximum short-circuit current breaking capacity (Icu)
at AC at 690 V rated value 6?kA
response value current
of instantaneous short-circuit trip unit 163?A
UL/CSA ratings
full-load current (FLA) for three-phase AC motor
at 480 V rated value 12.5?A
at 600 V rated value 12.5?A
yielded mechanical performance hp
for single-phase AC motor
at 110/120 V rated value 0.5?hp
at 230 V rated value 2?hp
for three-phase AC motor
at 200/208 V rated value 3?hp
at 220/230 V rated value 3?hp
at 460/480 V rated value 7.5?hp
at 575/600 V rated value 10?hp
Short-circuit protection
product function short circuit protection Yes
design of the short-circuit trip magnetic
Installation/ mounting/ dimensions
mounting position any
mounting type screw and snap-on mounting onto 35 mm standard mounting rail
according to DIN EN 60715
height 97?mm
width 45?mm
depth 97?mm
Ask questions
(0/1,200)
- Q: Can I place an order over the phone?
A: Yes, in some cases, you may be able to place an order over the phone. Please contact our customer service team and provide them with the necessary details to assist you with the phone order process.
- Q: How can I compare prices and reviews of similar products?
A: On the product list page, you can view the prices and ratings of different items simultaneously. You can also use filters to sort products by price or rating, facilitating your comparison and selection.
- Q: Can I place an order for an out-of-stock item?
A: If an item is currently out of stock, you may not be able to place an order for it. However, you can sign up for a notification to be informed when the item is back in stock.
Reviews
- J
JESUS ESPARZA
Aug 25, 2025
Siemens Circuit Breaker 3RV2023-1KA10Got the update on time and was super polite.HelpfulUnhelpful - J
James Schlobohm
Jun 08, 2025
Siemens Circuit Breaker 3RV2023-1KA10Fantastic prices and fast shipping, what more could I ask for?HelpfulUnhelpful - S
Samuel Keithley
Sep 06, 2024
Siemens Circuit Breaker 3RV2023-1KA10Exactly what I was looking for, shipped quickly and easily.HelpfulUnhelpful - R
Richard Fudjinski
Jan 21, 2024
Siemens Circuit Breaker 3RV2023-1KA10easy to locate produced and to view item.HelpfulUnhelpful - A
Anonymous user
Nov 25, 2022
Siemens Circuit Breaker 3RV2023-1KA10All was ok! No problems whatsoever.HelpfulUnhelpful
Siemens Circuit Breaker 3RV2023-1KA10
✔ In Stock (Can ship in 5-7 days)

Online Support 24/7
12 Months Warranty for New Products
30 Days Money Back Guarantee
People who bought this item also viewed
Fuji Circuit Breaker EW100EAG-3P063
Siemens Circuit Breaker 5SU9336-7CN25
Siemens Circuit Breaker 5SY7550-8CC
Siemens Circuit Breaker 5SY5206-6CC
Siemens Circuit Breaker 3WT8120-8UG00-0AA1
Siemens Circuit Breaker 3WT8120-5UG04-5AB1
Siemens Circuit Breaker 5SY7616-7CC
Siemens Circuit Breaker 5SY7515-8CC
TRIAD Transformer FS36-030-C2
Raychem Fuse RUEF600
Kacon Relay 730-1QR 220VAC
UniOhm Resistor 0402WGJ0394TCE
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
CKD Solenoid Valve AB31-01-1-AC110V
CKD Air Cylinder SMD2-L-DA-25-40
Copeland Compressor 4DB3R20M0-TSE-C00
TYCO Relay T7NS5D1-05
MAC Solenoid Valve 421A-B0A-DM-DDAJ-1KJ
MTL Encoder MEH-30-360P
Copeland Compressor ZB56KA-TW3-230
Siemens Contactor 3RF2350-1AA24