What should I do if there is ice jam in the cold and hot shock test box? During the environmental test, the thermal shock series and the thermal shock test chamber may have many problems, which may cause ice jams. How to solve this problem? Some people think that when large equipment such as the thermal shock series appears The problem, most people may think that only * maintenance personnel can perform repairs, but this is not the case. Stress screening cold and hot shock test box For cold and hot shock test box maintenance, ice blocking problem. As long as we recognize the cause of this problem, the user can repair it himself. When moisture enters the compressor of the cold and hot shock test box, and the compressor performs leak test under pressure, it will cause ice blocking problems in the cold and hot shock series and cold and hot shock test box equipment. To solve this, first of all, it is necessary to completely remove the moisture at the intake location, eliminate the moisture at this location, and prevent moisture from entering. This method is the key. Then, make a high-efficiency filter for the thermal shock test chamber. This filter is mainly used for drying. How to make this filter is actually very simple. In daily life, find an iron jar with a seal, then drill a round hole at the bottom, which does not need to be large, and then connect a piece of copper pipe to the round hole. After completion, put the calcium chloride in the nylon cloth bag, and finally put it in the iron can, and keep the lid tightly closed to prevent air from entering and causing moisture. In the process of using the compressor of the thermal shock test box, you only need to remove the plug, and then connect the exhaust port to the compressor air pipe.

Related Info
Main features of semi-closed scroll compressor Common failures and maintenance of overload protectors for air-conditioning compressors Judgment of the failure of piston compressor in starting Three factors determine the quality of cold storage Analysis of the reason why cold storage should not be built undergroundWhat should I do if there is ice jam in the cold and hot shock test box?
Subscribe to relevant news content?
Subscription
Unsubscription
Recent related posts
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
US$2307.69
Panasonic Servo Motor MHMF022L1V2M
US$653.85
Honeywell Solenoid Valve VE4025B1045
US$334.62
ROTEN Mechanical Seal 8E5K-22-X
US$384.62
Haier Air Conditioner KFR-32GW-01GKC13
Contact Us
SMC Proportional Valve ITV2050-113L
Contact Us
Autonics Rotary Encoder E40HB12-256-3-V-24
US$1153.85
AirTAC Air Cylinder ACPD40X25
US$28.46
MINDMAN Air Cylinder MCQV2-11-50-220M
US$105.77
Eaton Vickers Vane Pump V10-1S3S-1B20
US$338.46
Yaskawa Servo Motor SGMPH-04AAAGB6B
US$1080.00
Suntronix Fan SWQ108HD2
US$193.46