What are the protective devices of the air-cooled chiller refrigeration compressor? What is the role

What are the protective devices of the air-cooled chiller refrigeration compressor? What is the role 1. Internal thermostat (installed inside the compressor) In order to prevent the 24-hour uninterrupted operation of the air-cooled chiller, resulting in high-load operation of the compressor, defective electromagnetic switches, overcurrent caused by shaft holding, etc., or motor burnout caused by motor temperature, etc. The internal thermostat, which is installed on the neutral contact of the three-phase motor, protects the motor by cutting off the three phases at the same time when an abnormality occurs. Second, the electromagnetic switch The electromagnetic switch is to control the operation of the refrigeration compressor of the air-cooled chiller of the air-cooled chiller. The switch is stopped for the purpose of stopping, and it must be kept vertical during installation. If the installation is wrong, the pressure of the node spring will change, resulting in noise. , Resulting in lack of phase operation, for compressors equipped with a direct power-off protector, there is no need to load a protector. Three, reverse phase protector The structure of the scroll compressor and the piston compressor is different, and it cannot be reversed. The reverse phase of the three-phase power supply of the air-cooled chiller will cause the compressor to reverse, so it is necessary to install a reverse phase protector to prevent the refrigeration compressor from reversing . After the reverse phase protector is installed, the compressor can run in the normal phase, and does not operate in the reverse phase. When the reverse phase occurs, the two lines of the power supply can be changed to normal phase by swapping. Four, exhaust temperature protector In order to protect the compressor during high-load operation or lack of refrigerant, an exhaust temperature protector needs to be installed in the air-cooled chiller system. The exhaust temperature is set to 130±5°C to compress When the machine stops, this temperature value refers to the temperature detected by the compressor exhaust pipe within 10cm from the outlet. 5. Low-voltage switch In order to protect the air-cooled chiller compressor when the refrigerant is running low, a low-pressure switch is required. When it is set above 0.03mpa, the compressor stops running. Once the compressor is running in a state of insufficient refrigerant, the temperature of the compressor part and the motor part will rise instantaneously. At this time, the low-pressure switch can damage the compressor and the motor that the internal temperature and exhaust temperature protector cannot protect. Burn down for protection. 6. High voltage switch The compressor can be stopped when the high-pressure pressure rises abnormally, and the operating pressure is set below 3.0mpa.

Recent related posts

Customers frequently viewed