Three common faults and solutions of water-cooled air conditioners

Three common faults and solutions of water-cooled air conditioners Water-cooled air-conditioning failure 1. Water-cooled air-conditioning noise causes and troubleshooting   Water-cooled air conditioners are noisy and often affect the quality of sleep, which leads to irregular life and rest. At this time, the reasons and solutions of water-cooled air conditioner noises need to be considered:    1. The motor bearing is stuck, resulting in excessive noise from the air conditioner. Replace the motor bearing or replace the motor.    2. Loose motor fasteners.    3. During the transportation or installation of the air-conditioner, the fan cylinder is raised, and the fan cylinder should be adjusted.    4. In addition to the above failure reasons, the tuyere blades are loose and produce noise. The tuyere blades should be fixed tightly and the duct is not installed according to the design specifications, resulting in noise in the duct. At this time, the duct needs to be modified.    Water-cooled air-conditioning failure II. Reasons why water-cooled air-conditioning is not cooling    1. Check the water pump. If the water pump burns out, the water pump should be replaced.    2. The water supply pipe is clogged, and the water supply pipe should be cleaned.    3. The filter is too dirty, the filter should be cleaned.    4. The water distributor on the top of the filter net is clogged, and the water distributor should be cleaned.    5. The drain valve is stuck, the drain valve should be replaced.    6. The float valve is not adjusted correctly, the water level is too low, adjust the water level to 80-100 scale. 7.In addition to the above failure reasons, if the inlet water pressure is too low, if the float valve or solenoid valve does not enter the water, it will also cause no refrigeration. Water-cooled air-conditioning failure three, water-cooled air-conditioning leakage causes and troubleshooting methods    A. Water-cooled air conditioner leaks water from the inlet metal hose   If the water-cooled air conditioner in the home leaks at the water inlet metal hose, it means that the water inlet metal hose of the air conditioner is aging or cracked, resulting in water leakage from the hose. In this case, the metal hose of the water-cooled air conditioner needs to be replaced.   B. Water-cooled air-conditioning drain valve leakage    Drain valve leakage is the main cause of water-cooled air conditioning leakage. In this case, there are mainly these methods and steps to check    1. The chassis of the air conditioner is tilted, and the level of the air conditioner should be adjusted.    2. The gasket in the float valve is damaged, and the gasket should be replaced.    3. When installing the filter screen, the float valve is pressed by the filter screen, causing the float valve to continuously enter the water. The filter screen should be checked, and the profiled filter screen should be installed on the side of the float valve.    4. The drain valve is stuck by dirt and is not tightly closed. The dirt should be removed.    5. In addition to the above failure reasons, the inlet water pressure is too high, resulting in the float valve cannot be closed tightly, the water level is too high, causing leakage in the drain pipe.   C. Water leakage in the air duct of water-cooled air conditioner    1. Water-proof air-conditioning air duct waterproof glue comes off. When it rains, rain water leaks into the room from the gap of the air duct, and the waterproof glue should be re-filled.    2. Canvas soft joint installation is unqualified, too many folds, resulting in water accumulating on the canvas when it rains, and seeping into the air duct, the canvas soft joint should be adjusted.    3. The water distributor is too dirty, water is directly sucked into the fan from the water distributor, the water distributor should be cleaned.    4. The filter is broken, or burrs are generated on the inner surface of the filter, causing water to enter the fan. At this time, the filter needs to be replaced and the filter surface should be smooth.    5. The water inlet hose in the air conditioner is broken, and the water inlet hose should be replaced.

Recent related posts

What are the causes of air conditioning trip

06/20/2020

What are the causes of air conditioning trip

What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire.   Here are two formulas involved:   ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required.   ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current.    So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit.    Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle.    2. Leakage   During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip.   Why does the electric leakage cause the MCB to trip? There are two situations.    ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close.   ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open.   How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter.    ① Measure the voltage at the input and output to see if there is a significant change in voltage drop.   ②Measure whether the output current exceeds the standard.    So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.

Customers frequently viewed