The most common problems and solutions of adsorption dryers!
Adsorption dryer is a very important part of the compressed air purification process. Whether it operates normally and whether it is running well is directly related to the quality of compressed air. Therefore, enterprises should pay attention to the small problems that occur during the operation of adsorption dryers. The equipment should be inspected regularly to ensure the normal and efficient operation of the equipment. If the problem cannot be solved in time, it should be reported to the manufacturer for repair.
First of all, observe the operation process of the suction dryer, whether each controller corresponds to the corresponding actions of each solenoid valve and pneumatic valve. The adsorption dryer always maintains a full pressure in the adsorption chamber, and there will be a regeneration process when dry air enters the regeneration chamber. .
The most common problems and solutions of adsorption dryers
Mould core dryer adsorption stage:
Wet compressed air enters the air inlet buffer cavity from the inlet, and uniformly passes through the adsorption cavity of each mold core from bottom to top; the inner molecular sieve uses its own capillary action to absorb the moisture in the compressed air to achieve a drying effect.
The most common problems and solutions of adsorption dryers
Core dryer regeneration stage:
Micro heat regeneration, the regeneration dry air enters the regeneration unit outlet confluence chamber through the regeneration airflow regulating valve. After the high temperature dry gas expands and reduces to atmospheric pressure in the regeneration unit mold core adsorption cavity, the regeneration unit molecular sieve is purged and adsorbed from top to bottom. The agent will accelerate the separation of water and adsorbent in the body, resolve it in dry air, and discharge it from the muffler together with the regeneration gas.
The most common problems and solutions of adsorption dryers
Only by fully understanding the working process of the dryer can it be easier to deal with various problems that arise.
1. Abnormal pressure display
1, the pressure sensor is damaged
Treatment method: replace the new pressure sensor
2, the solenoid valve group is leaking or blocked
Treatment method: clean the solenoid valve seat and muffler, if damaged, must be replaced
3, the trachea is blocked or broken
Treatment method: check whether the tracheal ventilation is normal, if there is any abnormality, it must be replaced immediately
4, the valve seat pressure plate falls off or is damaged
Treatment method: check the pressure plate, replace if necessary
5, the cylinder is damaged
Treatment method: Check whether the cylinder is operating normally, replace it if necessary
6, check valve spring elastic deactivation
Treatment method: Replace the spring
7, the solenoid valve silencer is blocked
Treatment method: disassemble and clean the muffler, if it is blocked or damaged seriously, it must be replaced immediately
8. The regeneration air flow is too large
Treatment method: reduce the opening and closing degree of the (regeneration airflow) regulating valve (Note: the regeneration airflow regulating valve must ensure the same degree of opening and closing). If the check valve and intake valve are abnormal, replace them if necessary
2. The controller program works abnormally
1, the controller is damaged
Treatment method: check the controller, if it is damaged, it must be replaced immediately
3. After drying, the gas contains a small amount of moisture
1. With an air compressor to handle excessive flow or oil content, etc.
Treatment method: check whether the air compressor is working normally
2. There is a lot of rust inside the main gas supply pipeline, which blocks the muffler valve
Treatment method: empty the pipes and the rust inside the gas storage tank, and clean the bottom of the muffler.
Fourth, the dew point is too high
1. The intake air quality does not meet the specified standards
Treatment method: adjust intake pressure and temperature
2. The regeneration gas volume is too small
Treatment method: adjust the regeneration gas valve (make sure that the two groups open and close in the same degree), or contact BeiTeng after-sales service personnel
3, pipe
Treatment method: Whether the bypass valve is closed tightly, and whether the dried gas is connected with other pipeline gas
Five, fault shutdown
1, automatic power off
Cause analysis: circuit overload
Treatment method: check the circuit and replace the short-circuit component
2, low pressure shutdown
Cause analysis: intake air pressure is too low
Treatment method: adjust the intake air pressure to the specified standard
3, high temperature shutdown
Cause analysis: abnormal connection of temperature control module circuit, abnormal operation of solid state relay or temperature probe
Treatment method: check the connection line of the temperature control module, solid state relay and temperature probe, if there is any abnormality or damage, it must be replaced in time

Related Info
The difference between permanent magnet variable frequency air compressor and ordinary air compressor The essentials of air compressor selection The harm of screw air compressor not being maintained on time The importance of air compressor to laser cutting machine The invisible soul of air compressor operation-air filterThe most common problems and solutions of adsorption dryers!
Subscribe to relevant news content?
Subscription
Unsubscription
Recent related posts
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
US$2307.69
Panasonic Servo Motor MHMF022L1V2M
US$653.85
Honeywell Solenoid Valve VE4025B1045
US$334.62
ROTEN Mechanical Seal 8E5K-22-X
US$384.62
Bristol Compressor H71J323DBLK
Contact Us
BENNIC Capacitor 250V 13.9UF
US$3.04
KOYO PLC F4-08AD
US$1661.54
LG LS VFD Frequency Converter SV040iG5-4
US$653.85
VSDK Tool for Metal Cutting BT30-ATC
US$261.54
Bristol Compressor H22J183ABHL
Contact Us
LYC Bearing 51122
US$17.18
YUKEN Piston Pump A16-L-R-01-C-K-32
US$3000.00