The exhaust temperature of the unit is high (over 100℃)
The lubricating oil level of the unit is too low (the green position should be visible from the oil level mirror);
If the oil cooler is dirty, a special cleaning agent must be used for grease removal;
The oil filter core is blocked and needs to be replaced;
The temperature control valve is faulty (the component is broken), clean or replace;
Fan motor failure;
The cooling fan is damaged;
The exhaust duct is not smooth or the exhaust resistance (back pressure) is large;
The ambient temperature exceeds the specified range;
Temperature sensor failure

Related Info
Maintenance steps and methods of G series oil and gas separator Several PTA equipment process routes and equipment air compressor technology Smart vortex flowmeter Synthetic refrigerating oil for R22 screw machine: CP-4214-85, CP-4214-150, CP-4214-320, CP-4214-100 Technical standards for silent oil-free air compressorsThe exhaust temperature of the unit is high (over 100℃)