How to clean the central air conditioning system Many companies need the central air conditioner of the all-in-one machine to cool the equipment. If the equipment takes a long time or if one of the accessories in the system is broken, we need to replace it. If the equipment is used for a long time, many impurities will remain in the system. Today we are here to introduce the precautions and processes that Emerson Copeland compressor systems need to understand when cleaning and replacing compressors. In the future, it will be helpful for our engineers to help in cleaning and returning the compressor to the Copeland compressor system. First of all, we must first release the refrigerant in the Copeland compressor system, and remove the Copeland compressor compressor and drying filter system. We need to start a fire for this work. (First look at whether the unit you are constructing needs a fire certificate, if we need this, we need to do it in advance) If our work is to start a fire in the machine room, then it is best to put all the equipment in the machine room. The equipment is stopped, when the fire is moving, I am afraid that the flames will be blown everywhere. Our Copeland compressor system takes a long time to avoid not talking about the freezing oil on the surface of the copper tube. For safety reasons, we are best Hear all the equipment that can let out the wind. Then after we removed the Copeland compressor and the drying filter, we connected these copper pipes with copper pipes. After finishing, we cleaned the refrigeration system. We did the cleaning work outdoors. After cleaning the system, we will install the compressor and filter drier. This situation is the same as above. It is necessary to stop all equipment. After we cleaned the Copeland compressor system and installed the Copeland compressor and replaced the filter, we should conduct a gas tightness test on the Copeland compressor system, evacuate and charge the refrigerant. Finally, debug the Copeland compressor system.

Related Info
Precautions for cold storage acceptance Five items to pay attention to when using Copeland compressors Solutions to Copeland Compressor Insufficient Lubrication Failure Performance Difference between original and refurbished Emerson Copeland Scroll compressor How to maintain the refrigeration system on a daily basisHow to clean the central air conditioning system
Subscribe to relevant news content?
Subscription
Unsubscription
Recent related posts
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
US$2307.69
Panasonic Servo Motor MHMF022L1V2M
US$653.85
Honeywell Solenoid Valve VE4025B1045
US$334.62
ROTEN Mechanical Seal 8E5K-22-X
US$384.62
REXROTH Overflow Valve Z2DB6VC1-42/100V
Contact Us
TWOWAY Switch DNC-100K-06I
US$134.62
YUKEN Vane Pump PVR50-L-T56-LRA-3180
Contact Us
SKF Bearing 22268 CC/W33
US$3653.85
FUJI IGBT Module 2MBI300P-140-03
Contact Us
PAN WORLD Magnet Pump NH-405PW-C-AV
Contact Us
Sanyo Denki Servo Motor P30B08075DCSSEM
US$1080.00