How to choose refrigerant for high and low temperature alternating damp heat test chamber
There are many kinds of refrigeration used in the high and low temperature alternating damp heat test chamber, and different refrigerants have very different uses and application ranges. Today, we will focus on explaining the main refrigerants on the market.
One, low pressure and high temperature refrigerant
Condensing pressure Pk≤2—3kg/cm (absolute), evaporation temperature T0>0℃. Such as R11 (Freon 11, CFCL3, a fluorine, its T0=23.7℃), R21, R114, its T0=23.7℃. This type of refrigerant is suitable for centrifugal refrigeration compressors of air conditioning systems. Usually at 30℃, Pk≤3.06kg/cm.
Two, medium pressure temperature refrigerant
Condensing pressure Pk≤20kg/cm (absolute), 0℃>T0>-60℃. Such as R717 (ammonia, NH3), R12, R22 (freon 22, CHCLF2, difluoromonochloromethane), R502 (an azeotropic refrigerant, composed of R22 and R115 (pentafluoromonochloroethane, C2F5CL)), etc. This type of refrigerant is generally used in ordinary single-stage compression and two-stage compression piston refrigeration compressors.
Three, high pressure low temperature refrigerant
Condensing pressure Pk≥20kg/cm (absolute), T0≤-70℃. Such as R23 (Freon 23, CHF3), R13 (CF3CL), R14 (CF4), carbon dioxide (CO2), R503, ethane, ethylene, etc. These refrigerants are suitable for the low temperature part of cascade refrigeration equipment or -70℃ In the following cryogenic device.
After reading the above content, we learned that -70℃ high and low temperature alternating damp heat test box, high and low temperature damp heat test box, high and low temperature alternating test box, high and low temperature test box, rapid temperature change test box, constant temperature and humidity test box , High and low temperature impact test chamber, ultra-low temperature test chamber high temperature part uses medium temperature refrigerant (R404A), and low temperature part uses low temperature refrigerant (R23). So the refrigerant is very important for the high and low temperature alternating damp heat test chamber.

Related Info
Exploring the secrets of refrigerated compartments Four anti-corrosion methods for heat exchangers Frostbite, accidental ingestion... first-aid measures for refrigerants that must be mastered How should the two-way flow fresh air system be installed How to adjust the hydraulic balance of air conditioning systemHow to choose refrigerant for high and low temperature alternating damp heat test chamber
Subscribe to relevant news content?
Subscription
Unsubscription
Recent related posts
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
US$2307.69
Panasonic Servo Motor MHMF022L1V2M
US$653.85
Honeywell Solenoid Valve VE4025B1045
US$334.62
ROTEN Mechanical Seal 8E5K-22-X
US$384.62
Festo Sensor SIEF-M30NB-NS-S-L
US$115.00
Bristol Compressor H23B283DBDE
Contact Us
Schneider Relay LT3SA00M
US$322.00
OKO Bearing 6314CE/P2seal
US$38.46
CRYDOM Relay CSW2450-10
US$75.90
Copeland Compressor ZB19KA-TFV-950
Contact Us
Festo Air Cylinder DPZ-32-80-P-A-S6
US$809.62
SUNON Fan GB0545AFV1-8.B1824.GN
US$18.00
Schneider Circuit Breaker NSC100B3075N
US$625.00
Ebmpapst Fan 4656N/C03
US$123.08