Five damage situations known to the compressor

Five damage situations known to the compressor Air conditioning has always been an indispensable "good companion" to accompany the hot summer! The reason the air conditioner can bring us cool is because of its internal compressor. If the air conditioner is used more and more frequently, then its internal compressor is prone to malfunction or even damage.    Generally speaking, there are several common damage methods for air-conditioning compressors. Let's take a Hitachi compressor from compressor supplier okmarts.com as an example to give you a brief introduction.

refrigeration compressor,compressor,Mitsubishi Compressor,Bristol Compressor,HITACHI Compressor,Danfoss compressor

Case 1: If the coil winding of Hitachi compressor is burnt, the compressor cannot start normally, and the compressor has protection or burn-in features.   Case 2: Hitachi compressor damage may also be due to leakage. The air-conditioning compressor cannot start, and trips as soon as it is energized. This is because the compressor winding has a short circuit to ground or the insulation has decreased.   Case 3: Hitachi compressors have normal values ​​but are frequently protected. The overall performance is reduced, the working current of the winding is unstable, and the phenomenon of insufficient load capacity exists.   Case 4: Hitachi compressor starts normally without suction or discharge pressure or insufficient. The efficiency drops, the system pressure appears high, and the current value is lower than the rated value.   Case 5: The mechanical parts of Hitachi compressor are stuck (stuck cylinder). Due to the frequent operation of the protector, the compressor will be stuck. Of course, the compressor cannot be started at this time, but the winding resistance is normal.   Five conditions and five ways lead to Hitachi compressor damage. If in real life, no matter what kind of situation occurs, we must repair it in time to ensure that other components of the compressor are not involved. If you know that the damage is still running, this method is absolutely unavoidable! Do you understand the five types of compressor damage?

Recent related posts

Customers frequently viewed

New In stock for sale, IWAYA DENKI Water Pump 25CJT0752

IWAYA DENKI Water Pump 25CJT0752

US$2307.69
New In stock for sale, ROTEN Mechanical Seal 8E5K-22-X

ROTEN Mechanical Seal 8E5K-22-X

US$384.62
New In stock for sale, Balluff Sensor BES024P

Balluff Sensor BES024P

US$36.54
New In stock for sale, Sanyo Denki Fan 109S081

Sanyo Denki Fan 109S081

US$41.86
New In stock for sale, UNIVER Solenoid Valve AF-2700

UNIVER Solenoid Valve AF-2700

US$341.55
New In stock for sale, Beckhoff Module EL3068

Beckhoff Module EL3068

US$411.11
New In stock for sale, SKF Bearing 61918

SKF Bearing 61918

US$211.54