Causes of noise in circular cooling towers and noise reduction measures
Many people find that the noise is loud after purchasing a circular cooling tower. How do these noises occur? Let’s analyze it for you today.
1. The noise of the circular cooling tower is mainly caused by fans and falling water:
1. Fan noise of circular cooling tower: The greater the fan motor power, the greater the fan noise generally. Fan noise is low frequency noise, strong penetrating power, not easy to attenuate. The noise of the fans of the same power of the tower and the cross-flow tower are equal. Of course, there are also low-noise circular cooling towers.
2. Water falling noise of the circular cooling tower: the structure of the circular cooling tower is caused by the noise of water falling from the filler to the water surface of the collecting pan. The falling water noise is high frequency noise, which decays quickly. The packing of the cross flow tower is very close to the water collecting pan, and the noise of falling water is very small. Most of the towers are of circular structure, and most of the cross-flow towers are of square structure, so the circular cooling tower is relatively noisy.
2. What are the noise reduction measures for circular cooling towers:
1. Reasonable layout of circular cooling tower
Reasonable layout is to realize functional partitioning, separating movement and static. Due to the large noise source, the circular cooling tower should be arranged in areas with low noise requirements such as production areas or activity areas. Avoid getting too close to noise-sensitive buildings such as offices, dormitories, and residential areas, which may affect the work of employees and residents. Set noise protection distances between different functional areas of the circular cooling tower, and arrange buildings or rooms with relatively low noise requirements near the noise source side in the functional areas with higher environmental noise.
2, circular cooling tower base vibration reduction
is mainly to isolate the vibration of the equipment to reduce the impact of the equipment vibration on the structure.
3, circular cooling tower sound insulation
Under the condition of satisfying the wind exchange coefficient, a sound insulation facility circular cooling tower outer cover is installed on the outside of the circular cooling tower. Generally, the sound insulation measures can reach the effect of 156.
4. Circular cooling towers control the transmission route
When sound waves encounter obstacles, reflection and diffraction will occur, which reduces the energy of sound waves received by the external sound body. You can use natural shelters, or set up sound barriers, green belts, etc. to reduce the impact of noise.
Three, the application range of circular cooling tower:
(1) Metallurgical machinery, petrochemical, silicate industry
(2) Closed loop of soft water for blast furnace in ironworks;
(3) The cooling water system of the heating furnace, crystallizer and other devices of the steelmaking plant;
(4) Cooling water system of rolling mill and coking plant;
(5) Cooling water system of blower, motor, rolling mill and other equipment;
(6) Cooling water system for medium frequency induction furnace, medium and high frequency power supply and electric control, melting furnace, diathermic furnace, quenching furnace, vacuum furnace, induction holding furnace;
(7) Oil circuit cooling and grinding tool cooling of machining equipment; circular cooling tower for air compressor cylinder liner cooling.

Related Info
Why is the duct air conditioner not a central air conditioner Will the amount of refrigerant cause frost in the return pipe and compressor After reading this article, completely get rid of the phenomenon of centrifugal refrigeration compressor surge Analysis of refrigeration equipment system operation and introduction of energy-saving measures Causes and troubleshooting of refrigeration solenoid valve failureCauses of noise in circular cooling towers and noise reduction measures
Subscribe to relevant news content?
Subscription
Unsubscription
Recent related posts
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
US$2307.69
Panasonic Servo Motor MHMF022L1V2M
US$653.85
Honeywell Solenoid Valve VE4025B1045
US$334.62
ROTEN Mechanical Seal 8E5K-22-X
US$384.62
PHILIPS Capacitor 093 330UF 400V
US$8.77
Haier Air Conditioner KFR-26GW-81@U1-Jd
US$1153.46
Festo Air Cylinder DGRF-C-GF-32-400-P
Contact Us
Baumer Encoder GM400.0903106
Contact Us
Yaskawa Servo Motor SGMGH-44DCA6H
US$2692.31
Mcquay Air Conditioner MCC018T
US$2653.85
Yaskawa Servo Motor SGM-08A3NT11
US$769.23
CKD Solenoid Valve 3PB110-D2
US$46.15
F-TEC Air Cylinder DP601-HT
US$101.92