Be vigilant What is the hazard if the cooling tower is floating

Be vigilant What is the hazard if the cooling tower is floating

With the development of the times, cooling towers are widely used in various industries. Among them, the phenomenon of cooling tower floating water has a great impact on the safety of cooling tower operation and the safety of the surrounding equipment environment, so what are the hazards of cooling tower floating water? What? Let me explain to you.

1. Drifting water at the air duct-Drifting water at the air duct is the most serious part of the cooling tower. It mainly has a great impact on the corrosion of the surrounding environment, especially in winter, due to the large amount of floating water in the cooling tower. Large-area icing directly affects the normal operation of the cooling tower and the equipment and environment around the cooling tower.

2. Floating water at the air inlet-water floating at the air inlet is generally caused by excessive water pressure in the cooling tower or water splashing outwards caused by excessive water flow; due to the low temperature in winter, the air inlet is prone to icing. The position of the blinds in the wind is easy to be damaged by ice hangers.

  3. Severe water floating in the cooling tower will cause the loss of circulating water, and a large amount of water is required to meet the normal operation of the cooling tower. The floating water phenomenon of FRP cooling tower not only damages the surrounding environment, but also directly increases the economic expenditure of users.

  4. Solution: Drift water at the air duct can improve the spray system, add water baffles and water collectors and other water collection measures, and add water collection plates at the air inlet, which will greatly improve the water floating phenomenon of the cooling tower.

   In addition, the cooling tower inlet pressure is too large or the flow rate is too large, it will also cause the phenomenon of water floating in the cooling tower, it is recommended that the cooling tower flow is matched with the cooling tower model requirements, and the cooling tower circulating water pump is recommended to use large flow and low head.

   The above is the hazard phenomenon of cooling tower floating water. It can be seen how serious the hazard is. Therefore, it is essential for normal maintenance and repair. Only the correct maintenance of the cooling tower can ensure its normal operation and service life.