| Type | 3RV1 |
| Breaker Type | Motor Protection Circuit Breakers |
| Rated current | 16 |
| Number of Poles | 1 pole |
| Setting range for thermal overload releases | 11...16 A |
| Suitable for induction motors with P | 7.5 kW |
| Instantaneous overcurrent releases | 208 A |
| Short-circuit breaking capacity | 50 kA |
| Weight approx. | 0.436 kg |
Circuit breaker size S0 for motor protection CLASS 10 with overload
relay function A-release 11...16 A Short-circuit release 208 A Screw
terminal Standard switching capacity !!! Phased-out product !!!
Successor is SIRIUS 3RV2 Preferred successor type is >>3RV2121-
4AA10<<
product brand name SIRIUS
product designation circuit breaker
design of the product For motor protection with relay overload functionality
General technical data
product extension
auxiliary switch Yes
power loss W for rated value of the current
at AC in hot operating state 9.25 W
at AC in hot operating state per pole 3.1 W
surge voltage resistance rated value 6 000 V
protection class IP
on the front IP20
shock resistance 25g / 11 ms
mechanical service life (switching cycles)
of the main contacts typical 100 000
continuous current rated value 16 A
Ambient conditions
installation altitude at height above sea level
maximum
2 000 m
ambient temperature
during operation -20 ... +60 degrees centigrade
during storage -50 ... +80 degrees centigrade
during transport -50 ... +80 degrees centigrade
Main circuit
number of poles for main current circuit 3
adjustable pick-up value current of the currentdependent
overload release
11 ... 16 A
operating voltage
rated value 690 V
at AC-3 rated value maximum 690 V
operating current
at AC-3
at 400 V rated value 16 A
operating power
at AC-3
at 400 V rated value 7.5 kW
operating frequency
at AC-3 maximum 15 1/h
Auxiliary circuit
number of CO contacts
for auxiliary contacts 0
Protective and monitoring functions
product function
ground fault detection No
phase failure detection Yes
trip class CLASS 10
maximum short-circuit current breaking capacity (Icu)
at AC at 240 V rated value 100 kA
at AC at 400 V rated value 50 kA
at AC at 500 V rated value 10 kA
at AC at 690 V rated value 4 kA
Short-circuit protection
design of the overcurrent release and short-circuit
release
thermomagnetic
Installation/ mounting/ dimensions
mounting position any
mounting type screw and snap-on mounting onto 35 mm standard mounting rail
according to DIN EN 50022
height 97 mm
width 45 mm
depth 96 mm
required spacing
with side-by-side mounting
backwards 0 mm
at the side 0 mm
Connections/ Terminals
product function
removable terminal for auxiliary and control
circuit
No
type of electrical connection
for main current circuit screw-type terminals
for auxiliary and control circuit screw-type terminals
arrangement of electrical connectors for main current
circuit
front side
type of connectable conductor cross-sections
for main contacts
solid 2x (1 ... 2.5 mm?), 2x (2.5 ... 6 mm?)
stranded 2x (1 ... 2.5 mm?), 2x (2.5 ... 6 mm?)
finely stranded with core end processing 2x (1 ... 2.5 mm?), 2x (2.5 ... 6 mm?)
at AWG conductors for main contacts 2x (14 ... 10)
Ask questions
(0/1,200)
- Q: How can I unsubscribe from marketing emails?
A: To unsubscribe from marketing emails, you can click on the "Unsubscribe" link located at the bottom of the email. This will allow you to opt out of receiving further marketing communications from us.
- Q: How can I compare prices and reviews of similar products?
A: On the product list page, you can view the prices and ratings of different items simultaneously. You can also use filters to sort products by price or rating, facilitating your comparison and selection.
- Q: How can I participate in promotions or giveaways organized by sellers?
A: We regularly hold promotional events and organize giveaways and gift activities. You can follow our official announcements, emails, or social media channels to get information on how to participate and the details of these activities.
Reviews
- J
Jeff Browning
Aug 18, 2025
Siemens Circuit Breaker 3RV1121-4AA10Easy to use and customize settings.HelpfulUnhelpful - M
Mark Muellner
Aug 04, 2025
Siemens Circuit Breaker 3RV1121-4AA10The work was completed on schedule and the motor was packaged nicely.HelpfulUnhelpful - W
William Kahrs
Jul 27, 2025
Siemens Circuit Breaker 3RV1121-4AA10I'm so happy with the performance of this motor.HelpfulUnhelpful - G
Garret Chilson
Dec 09, 2024
Siemens Circuit Breaker 3RV1121-4AA10ExcellentHelpfulUnhelpful - L
Lazaro Diaz
Dec 07, 2024
Siemens Circuit Breaker 3RV1121-4AA10I'm really looking forward to receiving this product quickly.HelpfulUnhelpful - P
Phillip Mayfield
Sep 13, 2024
Siemens Circuit Breaker 3RV1121-4AA10Shipped out fast and arrived just as I wanted.HelpfulUnhelpful - A
Anonymous user
Nov 25, 2022
Siemens Circuit Breaker 3RV1121-4AA10All was ok! No problems whatsoever.HelpfulUnhelpful
Siemens Circuit Breaker 3RV1121-4AA10
✔ In Stock (Can ship in 5-7 days)

Online Support 24/7
12 Months Warranty for New Products
30 Days Money Back Guarantee
People who bought this item also viewed
Siemens Circuit Breaker 5SY5206-6CC
Siemens Circuit Breaker 5SY7632-7CC
Siemens Circuit Breaker 3WT8080-6UG00-0AA1
Siemens Circuit Breaker 5SY4450-7CC
GE Circuit Breaker FDN36TD125GD
SINGWAY Transformer 70
HITACHI Contactor K20BN-EP
OBO Surge Protection Device V50-1+FS-280
Schneider Fuse DF2CN20
LG LS Relay GTH-40/3 18-26A
UniOhm Resistor 0603WAJ0244T5E
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
PARKER Filter 929903Q
Ealy Vane Pump VDC-11BL-25D-25A-20
XINJE Servo Drive DS3-20P4
Copeland Compressor CR22KQ-TF5-980WB
Copeland Compressor ZR84KC-TFJ-250
AirTAC Air Cylinder SE80X675S
HENGSTLER Encoder RI76TD/10000ED.1N15KF
Kuebler Encoder 8.5020.832A.1024
Autonics Sensor PRL08-2DP
LG LS Relay GTH-85 34-50A