✔ In Stock (Can ship in 5-7 days)

Online Support 24/7
12 Months Warranty for New Products
30 Days Money Back Guarantee
| Type | 3RV2 |
| Breaker Type | Motor Protection Circuit Breakers |
| Rated current | 1 |
| Number of Poles | 1 pole |
| Setting range for thermal overload releases | 0.7...1 A |
Circuit breaker size S00 for motor protection, CLASS 10 with
overload relay function A-release 0.7...1 A N-release 13 A screw
terminal Standard switching capacity
product brand name SIRIUS
product designation Circuit breaker
design of the product For motor protection with overload relay function
product type designation 3RV2
General technical data
size of the circuit-breaker S00
size of contactor can be combined company-specific S00, S0
product extension
auxiliary switch Yes
power loss W for rated value of the current
at AC in hot operating state 7.25?W
at AC in hot operating state per pole 2.4?W
insulation voltage with degree of pollution 3 at AC
rated value
690?V
surge voltage resistance rated value 6?kV
maximum permissible voltage for safe isolation
in networks with grounded star point between
main and auxiliary circuit
400?V
protection class IP
on the front IP20
of the terminal IP20
shock resistance
acc. to IEC 60068-2-27 25g / 11 ms
mechanical service life (switching cycles)
of the main contacts typical 100?000
of auxiliary contacts typical 100?000
electrical endurance (switching cycles)
typical 100?000
reference code acc. to DIN EN 81346-2 Q
Ambient conditions
installation altitude at height above sea level
maximum
2?000?m
ambient temperature
during operation -20?...?+60?degrees centigrade
during storage -50?...?+80?degrees centigrade
during transport -50?...?+80?degrees centigrade
temperature compensation -20?...?+60?degrees centigrade
relative humidity during operation 10?...?95?%
Main circuit
number of poles for main current circuit 3
adjustable pick-up value current of the currentdependent overload release
0.7?...?1?A
operating voltage
rated value 690?V
at AC-3 rated value maximum 690?V
operating frequency rated value 50?...?60?Hz
operating current rated value 1?A
operating current
at AC-3
at 400 V rated value 1?A
operating power
at AC-3
at 230 V rated value 180?W
at 400 V rated value 250?W
at 500 V rated value 370?W
at 690 V rated value 550?W
operating frequency
at AC-3 maximum 15?1/h
Auxiliary circuit
design of the auxiliary switch laterally
number of NC contacts for auxiliary contacts 0
number of NO contacts for auxiliary contacts 0
number of CO contacts
for auxiliary contacts 0
operating current of auxiliary contacts at AC-15
at 24 V 1.5?A
at 230 V 1.5?A
operating current of auxiliary contacts at DC-13
at 24 V 1?A
Protective and monitoring functions
product function
ground fault detection No
phase failure detection Yes
trip class CLASS 10
design of the overload release thermal
operational short-circuit current breaking capacity
(Ics) at AC
at 240 V rated value 100?kA
at 400 V rated value 100?kA
at 500 V rated value 100?kA
at 690 V rated value 100?kA
maximum short-circuit current breaking capacity (Icu)
at AC at 240 V rated value 100?kA
at AC at 400 V rated value 100?kA
at AC at 500 V rated value 100?kA
at AC at 690 V rated value 100?kA
response value current
of instantaneous short-circuit trip unit 13?A
UL/CSA ratings
full-load current (FLA) for three-phase AC motor
at 480 V rated value 1?A
at 600 V rated value 1?A
yielded mechanical performance hp
for three-phase AC motor
at 575/600 V rated value 0.5?hp
contact rating of auxiliary contacts according to UL C600 / R300
Short-circuit protection
product function short circuit protection Yes
design of the short-circuit trip magnetic
design of the fuse link
for short-circuit protection of the auxiliary switch
required
fuse gL/gG: 6 A, quick: 10 A
design of the fuse link for IT network for short-circuit
protection of the main circuit
at 500 V gL/gG 10 A
at 690 V gL/gG 10 A
Installation/ mounting/ dimensions
mounting position any
mounting type screw and snap-on mounting onto 35 mm standard mounting rail
according to DIN EN 60715
height 97?mm
width 65?mm
depth 97?mm
Ask questions
(0/1,200)
- Q: Can I request a specific delivery date for my order?
A: While we strive to deliver orders promptly, specific delivery date requests may not always be possible due to logistics and carrier limitations. However, if you have a specific requirement or need expedited shipping, please contact our customer service, and we will do our best to assist you.
- Q: What should I do if I forgot my password?
A: If you forgot your password, click on the "Forgot Password" link on the login page. Follow the instructions to reset your password.
- Q: Do you offer free shipping?
A: We may offer free shipping on select products or as part of promotional campaigns. You can check the product details or promotions to see if free shipping is available.
Reviews
- S
Sean Grady
Aug 12, 2025
Siemens Circuit Breaker 3RV2111-0JA10I'm extremely pleased with the product's durability.HelpfulUnhelpful - B
Brett Walker
Jul 07, 2025
Siemens Circuit Breaker 3RV2111-0JA10Your assistance was superb.HelpfulUnhelpful - B
BRIAN TRAXLER
Sep 07, 2024
Siemens Circuit Breaker 3RV2111-0JA10Fast delivery, thanks so much.HelpfulUnhelpful - J
Joseph Gonzales
Mar 10, 2024
Siemens Circuit Breaker 3RV2111-0JA10Pleasant and everything went smoothly~HelpfulUnhelpful - A
Anonymous user
Nov 25, 2022
Siemens Circuit Breaker 3RV2111-0JA10All was ok! No problems whatsoever.HelpfulUnhelpful
Siemens Circuit Breaker 3RV2111-0JA10
✔ In Stock (Can ship in 5-7 days)

Online Support 24/7
12 Months Warranty for New Products
30 Days Money Back Guarantee
People who bought this item also viewed
Siemens Circuit Breaker 5SY7405-7CC
Siemens Circuit Breaker 3WT8041-7UG00-0AA1
Siemens Circuit Breaker 5SY6614-7CC
Siemens Circuit Breaker 3WN6461-0HV58-0AK1
Terasaki Circuit Breaker TL-100C
Eaton Moeller Circuit Breaker FAZ-B13/3
Delixi Transformer JBK-100VA
Siemens Contactor 3RA2434-8XH32-1NB3
Tyco Fuse RUEF800
TOWARD Relay AC30S
UniOhm Resistor 201007J0113T4E
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
NSK Bearing MF 683
CKD Solenoid Valve 4F110-08-C2-AC220V
SUNX Sensor GX-M12B-P-Z
Copeland Compressor ZPD154KCE-TWD-522
Ebmpapst Fan G2E140PI2814